HMX6801
+
B2/C2 and HMX6801
+
B4/C4 Installation and Operation Manual
81
Appendix B: Troubleshooting Tips
Common Problems and Suspected Failures
+
Pilot Lite Fails to Communicate with Installed Modules
Confirm that the following items are not the reason for the
communication failure:
•
Proper module slot has not been specified (
+
Pilot Lite is not
communicating with the appropriate slot). See your
Frame Installation and Operation Manual
for more information on
slot identification.
•
COM port is used elsewhere (
+
Pilot Lite is not communicating
with the correct COM port).
•
Actual Slot ID and Frame ID do not match with the two DIP switch
settings in back of frame (
+
Pilot Lite is not communicating with
the appropriate slot and frame). See your
Frame
Installation and Operation Manual
for more information on Slot ID
and Frame ID DIP switch settings.
•
ICE6800
+
module is installed in the frame (
+
Pilot Lite control is
disabled if an ICE6800
+
module is installed in the frame;
ICE6800
+
modules are used for CCS control).
+
Pilot Lite Does Not Find All Modules in Frame
If a discovery is started too soon after frame power-up,
+
Pilot Lite will
not find all the installed modules. Refresh
+
Pilot Lite (
File
>
Refresh
),
and ensure that installed modules are fully powered-up first before
discovery.
+
Pilot Lite or CCS Software Application Not Responding
+
Pilot Lite and CCS applications cannot run on the same PC at the
same time. Both applications can be installed, but only one can be
opened at a time.