Chapter 2: Installation
Your upgrade procedure is complete.
If for some reason the upgrade fails, the module may not respond to
controls and will appear to be non-functional. In that event, follow the
procedures described in
“Correcting a Failed Upgrade Procedure” on
.
Discovering Devices Using the Drag-and-Drop Method
If you cannot discover your HMX6801
+
module using the
Discovery
tool, use this method to discover it:
1. With your CCS software in Build mode, drag or copy and paste the
module’s device icon from the
Catalog
folder into the
Network
or
Discovery
folder.
2. Right-click the device icon and then select
Properties
.
3. On the
Device
tab of the
Navigation Properties
box, enter the IP
address of the frame that holds the module. (See
.)
Figure 3.
Navigation Properties Box
4. In the third field, enter the slot number of the HMX6801
+
module,
and then close the window.
You can now continue upgrading your HMX6801
+
module’s firmware,
starting with step 3 in
“Upgrading Firmware” on page 16
.
Caution
Do not make changes in the last
Device ID field (located above
and to the right of the
Set
Default
button.)
Do not make changes in
this field
Enter frame IP number here