![Harris DiamondCD Series Technical Manual Download Page 53](http://html1.mh-extra.com/html/harris/diamondcd-series/diamondcd-series_technical-manual_4042094053.webp)
3/6/08
888-2463-001
2-23
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Diamond Series™
Figure 2-9 Power Supply Locations, Front View
STEP 6
Navigate to the Amplifier Cabinet screen and turn on the details with the
“SHOW” button. The module output power should be displayed. Slowly
raise the Exciter power until the enabled modules reach about 100W (on
the GUI screen) while watching the cabinet’s forward and reflected
power on the power meters. The cabinet power will be lower than the
sum of the module outputs until most of the modules are turned ON.
With only 2 modules operating, the cabinet output power will be very
low.
STEP 7
If there is nearly zero reflected power, turn ON the next power supply,
then press the transmitter ON button. Verify that the next two
corresponding modules are now producing power and there is minimal
cabinet reflected power.
STEP 8
Repeat STEP 7 while watching the forward and reflected power meters
until all the power supplies and modules are turned ON. The reflected
Power Supply 1
Power Supply 2
Power Supply 3
Power Supply 4
Power Supply 6
Power Supply 5
Power Supply 7
Power Supply 8
Supplies Modules
1 and 2
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
3 and 4
11 and 12
7 and 8
15 and 16
13 and 14
5 and 6
9 and 10
Power Supply 1
Power Supply 2
Power Supply 3
Power Supply 4
Power Supply 5
Power Supply 6
Supplies Modules
1 and 2
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
Supplies Modules
3 and 4
11 and 12
15 and 16
13 and 14
5 and 6
Power Supply configuration for 12 module cabinet
with new style combiner
Power Supply configuration for all cabinets with old style combiner
and 4, 6, 8 and 16 module cabinets with the new style combiner
Empty
Empty