5000/5100 Series Digital Analog Clocks Installation and Operation Manual

3

 Chapter 1: DAC-5000 Series Digital Analog Clocks

Installation

Wall Mounting

Figure 1-1. 

Typical Wall Mount

The DAC-5008, DAC-5012 and DAC-5016 Digital Analog Clocks are 
designed for wall mounting. Rack mounting kits are optional. 
The rear panels of both the DAC-5012 and DAC-5016 clocks are 
provided with four rubber feet and four keyholes while the DAC-5008 
has only three keyholes. These are dimensioned for #8 screws. The rear 
panel also has a large depression to contain the connecting wires and 
allow the clock to be placed close to the wall. 

Summary of Contents for DAC-5016

Page 1: ...5000 and 5100 Series Digital Analog Clocks Installation and Operation Manual Edition D 5000 5100 MAN ...

Page 2: ......

Page 3: ...Edition D August 2006 5000 5100Series Digital Analog Clocks Installation and Operation Manual ...

Page 4: ...PPER RouterWORKS Signal Quality Manager SpyderWeb SuiteView TitleMotion UNIFRAME Velocity VelocityHD VideoCarte Videotek and X75 are trademarks of the Harris Corporation which may be registered in the United States Canada and or other countries All other trademarks are the property of their respective owners Copyright 2006 Harris Corporation All rights reserved This publication supersedes all prev...

Page 5: ... Servicing v Returning a Product v Restriction on Hazardous Substances RoHS Compliance vi Waste from Electrical and Electronic Equipment WEEE Compliance vii Safety viii Safety Terms and Symbols in this Manual viii Chapter 1 DAC 5000 Series Digital Analog Clocks Overview 1 Introduction 2 Installation 3 Wall Mounting 3 Rack Mounting 5 Rear Panel 6 Control Modes 8 Calibration of the Internal Time Bas...

Page 6: ...cal 13 Chapter 2 ADC 5100 Series Analog Digital Clocks Overview 15 Introduction 16 Installation 18 Wall Mounting 18 Rack Mounting 20 Desk Mounting 20 Rear Panel 21 Control Modes 23 General Operation 24 Clock Control Modes 24 Clock Setting 26 Troubleshooting 32 Hands are Offset 32 Specifications 34 Electrical 34 Inputs and Outputs 34 Time Base 34 Controls 35 Mechanical 35 ...

Page 7: ...specifications for 5000 5100 Series Digital Analog Clocks Audience This manual is written for engineers technicians and operators responsible for installation setup maintenance and or operation of 5000 5100 Series Digital Analog Clocks Revision History Table P 1 Revision History of Manual Edition Date Comments C December 1998 Full release D August 2006 Manual reformatted and updated ...

Page 8: ...eets fields buttons check boxes list boxes combo boxes menus submenus windows lists and selection names Italics Indicates E mail addresses the names of books or publications and the first instances of new terms and specialized words that need emphasis CAPS Indicates a specific key on the keyboard such as ENTER TAB CTRL ALT or DELETE Code Indicates variables or command line entries such as a DOS en...

Page 9: ...ot designed for field servicing All upgrades modifications or repairs require you to return the product to the Customer Service center Returning a Product In the unlikely event that your product fails to operate properly please contact Customer Service to obtain a Return Authorization RA number then send the unit back for servicing Keep at least one set of original packaging in the event that a pr...

Page 10: ...ycling The Directive takes effect on July 1 2006 and it refers to the following hazardous substances Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr V1 Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE According to this EU Directive all products sold in the European Union will be fully RoHS compliant and lead free See our Web site www broadcast harris com leitch for more inform...

Page 11: ...sers will be required to recycle electrical and electronic equipment at end of its useful life and may not dispose of the equipment in landfills or by using other unapproved methods Some EU member states may have different deadlines In accordance with this EU Directive companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycl...

Page 12: ...oading If this product relies on forced air cooling it is recommended that all obstructions to the air flow be removed prior to mounting the frame in the rack If this product has a provision for external earth grounding it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel IMPORTANT Only qualified personnel should perform service procedures Safety ...

Page 13: ...es Digital Analog Clocks Overview This chapter provides installation and operation information about the DAC 5000 Series digital analog clocks It includes the following topics Introduction on page 2 Installation on page 3 Control Modes on page 8 General Operation on page 9 Specifications on page 12 ...

Page 14: ... Timecode SMPTE or EBU 12 VDC Impulse Clock Internal Time Base Line Frequency Reference All clock models accept Serial Timecode are in either the SMPTE or EBU format If reception of the timecode is lost the error LED located on the clock s face will light up and the clock will automatically switch to either the Internal Time Base or the Line Frequency Reference as selected on the back panel switch...

Page 15: ...DAC 5016 Digital Analog Clocks are designed for wall mounting Rack mounting kits are optional The rear panels of both the DAC 5012 and DAC 5016 clocks are provided with four rubber feet and four keyholes while the DAC 5008 has only three keyholes These are dimensioned for 8 screws The rear panel also has a large depression to contain the connecting wires and allow the clock to be placed close to t...

Page 16: ... inches from the mounting keyhole centers to the outside edge of each clock Table 1 1 Clock Wall Mounting Specifications Clock Overall Dimensions Mounting Keyhole Centers DAC 5016 17 45 17 45 in 16 0 15 5 in 4 keyholes DAC 5012 13 95 13 95 in 12 0 10 5 in 4 keyholes DAC 5008 10 45 10 45 in 8 0 8 0 in 3 keyholes The bottom single keyhole is located Table 1 2 Clock Clearances Clock Clearances Inches...

Page 17: ...ide screws placing the rack mount in position and reinstalling the screws The rack mount kits are designated as 5008RM 5012RM and 5016RM respectively The DAC 5006 clock is pre designed to be rack mounted and does not require the optional rack mounting kit It has an overall dimension of 7 19 inches Table 1 3 lists the required rack space for each clock Table 1 3 Required Space For Rack Mounting Clo...

Page 18: ...d AC connector for the power feed of the unit can be found in the recessed area running across the middle of the rear panel Spring Loaded Speaker Type Connectors red and black Push Buttons CW CCW MANUAL SET DIP Switches Clock Modes factory set AC Connector plug 115 230 VAC 10 250 60Hz 25VA Max OPERA TIONMODE DAC 5012 DAC 5016 230VAC 115VAC LINEVOLTAGE DAC 5008 50HZ 60HZ LINEFREQUENCY 1 2 4 3 5 6 O...

Page 19: ...ht Rear Panels MANUAL SET CCW CW 115 230 VAC 0 50 60Hz 25VA Max 2 1 2 4 3 5 6 OPEN Run on Secondary Use Offset Secondary Ref Line Time Code Format EBU Not Used Normal Normal Internal SMPTE Primary Ref Time Code 230 VAC 115 VAC LINE VOLTAGE 50 HZ 60 HZ LINE FREQUENCY MANUAL SET CCW CW 115 230 VAC 0 50 60Hz 25VA Max 2 1 2 4 3 5 6 OPEN Run on Secondary Use Offset Secondary Ref Line Time Code Format E...

Page 20: ...f the Internal Time Base The only equipment required is a high resolution frequency counter Connect the frequency counter to the clock test point provided at pin 9 of the CMOS NSC800N Microprocessor IC11 Adjust the 6 25 pF trimmer capacitor connected to pin 11 of IC11 until the counter indicates 2 457 600 Hz It is recommended to use the longest sampling time possible Table 1 4 Clock Control Mode D...

Page 21: ...r LED will go off to indicate that the unit is synchronized with the timecode If there is a change in the timecode the error LED will activate again while the microprocessor verifies the code to ensure that there is a valid time change and not a transient condition This verification requires 30 consecutive full code frames or 1 second for SMPTE format operation and 1 2 seconds for EBU format depen...

Page 22: ... detection positions However to establish the minute hand the position of the second hand must be already established To establish the hour hand the position of both the minute and second hands must also be established The error LED will not be on when operating as an impulse clock Secondary Reference Mode The DAC 5000 Series clock will run as a standard wall clock with no exterior Timecode or Imp...

Page 23: ...er the MANUAL SET button is released Use Offset The USE OFFSET function allows the addition of a user programmed constant offset to the user bits of a standard timecode Therefore the availability of a timecode generator capable of programming the user bits of the timecode is essential This function is generally used when it is desired to simultaneously provide GMT and local time with two clocks be...

Page 24: ... VAC 20 Frequency 50 or 60 Hz selectable Power 25 VA max Table 1 6 Primary Drive Inputs Input Item Specification Serial timecode SMPTE EBU Impedance Hi Z balanced Maximum voltage 100 Vp p Common mode rejection 55 dB Level 4 Vp p 12 dB Impulse drive 12 VDC 6 dB bipolar Impedance Hi Z balanced Maximum voltage 100 Vp p Common mode rejection 55 dB Level 4 Vp p 12 dB Table 1 7 Secondary Time Bases Item...

Page 25: ...9 1 lbs 4 1 kg DAC 5012 Style Wall mount Face diameter 11 75 in 298 mm Overall dimensions 13 95 13 95 2 8 in 354 354 71 mm Weight 7 3 lbs 3 3 kg DAC 5008 Style Wall mount Face diameter 8 in 203 mm Overall dimensions 10 45 10 45 2 8 in 265 265 71 mm Weight 5 lbs 2 3 kg DAC 5006 Style Rack mount Face diameter 5 in 127 mm Overall dimensions 7 19 2 8 in 177 482 71 mm Weight 4 5 lbs 2 Kg DAC 5005 Style...

Page 26: ...14 5000 5100 Series Digital Analog Clocks Installation and Operation Manual Chapter 1 DAC 5000 Series Digital Analog Clocks ...

Page 27: ...al Clocks Overview This chapter provides installation and operation information about the ADC 5100 Series digital analog clocks It includes the following topics Introduction on page 16 Installation on page 18 Control Modes on page 23 General Operation on page 24 Troubleshooting on page 32 Specifications on page 34 ...

Page 28: ...locks may operate with either a sweep or step second hand and will automatically decode either SMPTE or EBU timecode inputs Additionally the ADC may function as a timecode generator when operated from its internal crystal Either SMPTE or EBU timecode may be generated and used to drive other clocks in Master Mode Note Internal connector P1 must be reversed for Master Operation The ADC Series clocks...

Page 29: ...econdary timebase permanently and the error LED will be extinguished The following models are available ADC 5116 16 inch wall mounting Rack mounting and light kit optional ADC 5112 12 inch wall mounting Rack mounting and light kit optional ADC 5108 8 inch wall mounting Rack mounting and light kit optional ADC 5106 5 inch rack mounting Light optional ADC 5105 5 inch desk top mounting Light optional...

Page 30: ...12 and ADC 5116 Analog Digital Clocks are designed for wall mounting Rack mounting kits are optional The rear panels of both the ADC 5112 and ADC 5116 clocks are provided with four rubber feet and four keyholes while the ADC 5108 has only three keyholes These are dimensioned for 8 screws The rear panel of all three clocks is recessed for connectors and to allow the clock to be placed close to the ...

Page 31: ...ounting keyhole centers to the outside edge of each clock Table 2 9 Clock Wall Mounting Specifications Clock Overall Dimensions Mounting Keyhole Centers ADC 5116 17 5 17 5 in 16 0 15 5 in 4 keyholes ADC 5112 14 0 14 0 in 12 0 10 5 in 4 keyholes ADC 5108 10 5 10 5 in 8 0 7 75 in 3 keyholes The bottom single keyhole is located 0 35 in to the right of the center line Table 2 10 Clock Clearances Clock...

Page 32: ...the screws The rack mount kits are designated as RM 5116 RM 5112 and RM 5108 respectively The ADC 5106 clock is pre designed to be rack mounted and does not require the optional rack mounting kit It has an overall dimension of 7 19 inches Table 2 11 lists the required rack space for each clock Desk Mounting The ADC 5105 clock can simply be set or mounted on any desk surface Its overall dimensions ...

Page 33: ...configured for timecode input slave operation unless otherwise specified when ordering The clock type and operating voltage are also indicated on the rear panel A standard AC connector for the power feed of the unit can be found in the recessed area running across the middle of the rear panel 115 230 VAC 10 50 60Hz 15VA Max 1 2 4 3 5 6 O P E N Tim eCode SM P TE Internal Norm al Norm al StepSeconds...

Page 34: ...W 115VAC 230VAC OPERATION MODE SLAVE MASTER ADC 5105 L ADC 5105 Line Voltage 115 230 VAC 10 50 60Hz 15VA Max 1 2 4 3 5 6 OPEN Run on Secondary Use Offset Secondary Ref Line Time Code Format EBU Not Used Step Seconds Normal Normal Internal SMPTE Primary Ref Time Code MANUAL SET CCW CW 115VAC 230VAC OPERATION MODE SLAVE MASTER ADC 5106 L ADC 5106 Line Voltage 115 230 VAC 10 50 60Hz 15VA Max 1 2 4 3 ...

Page 35: ... 12 lists the Clock Control mode DIP switch options Note Changes to the DIP Switch settings other than SW3 made during clock self setting will NOT be recognized until the clock has finished setting Table 2 12 Clock Control Mode DIP switch options Dip Switch Switch Options Open Closed SW1 Timecode Impulse SW2 SMPTE EBU SW3 Internal Line SW4 Normal Use offset SW5 Normal Run on secondary SW6 Secondar...

Page 36: ...mal operation following self set for the second hand to completely re synchronize This is due to accumulated gear slippage during counter clockwise movements If there is a failure of the input timecode the clock will switch to the Secondary Reference as selected by DIP switch SW4 on the rear panel Either the clock s own internal crystal or the power line frequency may be selected as the secondary ...

Page 37: ...clock will automatically self set to the correct time The internal battery backed timekeeping function will maintain time for up to two years in the absence of external power Auxiliary Offset DIP switch SW3 allows access to a user programmed auxiliary offset from the input timecode s user bits The timecode source however must have the ability to generate the correct information in the user bits Th...

Page 38: ...s remove the 10 screws along the outside edge of the clock Carefully lift the rear panel from the chassis taking care not to disturb the cables connected to the motor assembly If the cables become disconnected the time shown on the hands may become offset from the real time in which case see Clock Setting on page 26 Follow the two wires from the speaker type terminals to their connector on the PC ...

Page 39: ...ode generating clock The clock hands must be offset for a different time zone The offset must be removed For example an offset of hours minutes or seconds may have been inadvertently applied if the rear buttons were actuated without following the correct procedure In this case the hands and the internal microprocessor must both be set to the same time The clock will then display the correct time w...

Page 40: ...CW button causes the hands to move counter clockwise When pressed once the hands move backwards 50 seconds If the CCW button is held down the hands accelerate until full speed is reached To stop the hands re press the CCW button Setting the Time in Master Clock or Stand Alone Modes To set the time in Master Clock or Stand Alone modes follow these steps 1 Follow the steps described in Repositioning...

Page 41: ...CW and CCW buttons as described in Repositioning the Hands on page 28 For example to apply a 4 hour offset set the hands to 4 00 If the hands are a long way off the process may take up to 15 minutes A short cut method is described in Hands are Offset on page 32 4 Once the hands are positioned at the appropriate time press and hold the MANUAL SET button until the error LED flashes While still holdi...

Page 42: ...ylight saving time is applied to the master clock not the ADC Second Hand Tracking If the second hand is not falling on the second marks the following calibration procedure should be used while the clock is operating normally Be careful not to enter the Manual Set Mode Note Before moving the seconds hands place the hands in Step Mode using DIP switch SW1 closed position To advance the second hand ...

Page 43: ...ter clockwise press and hold the CCW and MANUAL SET buttons together in the following manner press and hold the CCW button first followed by the MANUAL SET button For every second that the buttons are held the hands will move three extra motor points backward There are 150 motor points per second therefore a one second error requires that the CCW and MANUAL SET buttons be held for 50 seconds When ...

Page 44: ...is method follow these steps 1 Disconnect the timecode The front LED will flash twice per second 2 Press and hold the MANUAL SET button until the LED stays illuminated 3 Using the CW and or CCW buttons as described in the section Repositioning the Hands on page 28 position the hands to the top of the nearest hour 4 Press and hold MANUAL SET The error LED will start to flash 5 While holding MANUAL ...

Page 45: ... 5100 Series Digital Analog Clocks Installation and Operation Manual 33 Chapter 2 ADC 5100 Series Analog Digital Clocks 7 Release the CCW button and then release the MANUAL SET button 8 Re connect timecode ...

Page 46: ...AC 20 selectable Frequency 50 or 60 Hz automatic selection Table 2 15 Inputs Item Specification Serial timecode SMPTE EBU Impedance Hi Z balanced Level 4 Vp p 8 dB Table 2 16 Outputs Item Specification Serial timecode SMPTE EBU non drop frame Impedance Lo Z balanced Level 10 dB nominal unloaded 3dB into 180 Ohms Table 2 17 Time Base Item Specification Timecode SMPTE EBU automatic selection Interna...

Page 47: ...SD 5300 Table 2 19 Mechanical Specifications Clock Item Specification ADC 5116 Style Wall mount Face diameter 16 in 406 mm Overall dimensions 17 5 17 5 3 375 in 445 445 86 mm ADC 5112 Style Wall mount Face diameter 11 5 in 292 mm Overall dimensions 14 0 14 0 3 375 in 356 356 86 mm ADC 5108 Style Wall mount Face diameter 8 in 203 mm Overall dimensions 10 5 10 5 3 375 in 267 267 71 mm ADC 5106 Style...

Page 48: ...36 5000 5100 Series Digital Analog Clocks Installation and Operation Manual Chapter 2 ADC 5100 Series Analog Digital Clocks ...

Page 49: ......

Page 50: ...ason OH USA 45040 Tel 1 513 459 3400 www broadcast harris com 2006 Harris Corporation Harris and Leitch are registered trademarks of Harris Corporation Trademarks and tradenames are the property of their respective companies A brand of Harris Corporation ...