Chapter 4: Parameters, LEDs, and Alarms
APM6800-D2
+
D/APM6801-D2
+
D Parameters
In addition to the APM6800
+
/APM6801
+
APM6800-D2
+
D/APM6801-D2
+
D modules also have the parameters from
.
.
Table 4-4. APM6800-D2
+
D/APM6801-D2
+
D Parameters
Parameter Name
Ba
nk,
Switch
Function
Options
General
Dolby Encoder Ver
Displays the version number of the
firmware
<string>
Serial Port Interface
0, 1
Sets the serial port interface
• RS-232
•
RS-422
Input > Genlock/DARS
Lock Source Select
0, A
Sets the locking source for the
module
•
Genlock
• DARS
• Dolby Enc Ch 1 Src
Processing > Dolby
Guard Band Offset
2, B
Adjusts the guard band location
•
0
Ln to 524 Ln (525)
•
0
Ln to 624 Ln (625)
•
0
Ln to 749 Ln (720)
•
0
Ln to 1124 Ln (1080)