ACO6800
+
Installation and Operation Manual
79
Copyright © 2009, Harris Corporation
Chapter 7: ACO6800
+
ASID Parameters, LEDs, and Alarms
Monitoring LEDs
Module Status LEDs
The ACO6800
+
ASID module does not have any card-edge alarms. Instead, the
module status LED on the corner of the module lights up if an error is detected.
See
for the location of the LED, and
for a
description of the LED colors.
Note
If the LED is flashing red, contact your Customer Service representative.
Alarms
If a major or minor alarm is triggered within your modules, the Status LED will
light red.
Table 7-2. ACO6800
+
ASID Monitoring LEDs Indicators
LED
Name
Description
Color Indication
1
Out A LED 1
The current selected input is 1A for group A.
Green
2
Out A LED 2
The current selected input is 2A for group A.
Green
3
IN 1A Present
Input 1A signal is present.
Green
4
IN 1A Alarm
Input 1A is in an alarm state.
Amber
5
IN 2A Present
Input 2A signal is present.
Green
6
IN 2A Alarm
Input 2A is in an alarm state.
Amber
7
Out B LED 1
Not Used
8
Out B LED 2
9
IN 1B Present
10
IN 1B Alarm
11
IN 2B Present
12
IN 2B Alarm
Table 7-3. Module Status LED Descriptions
LED Color
Sequence
Meaning
Off
There is no power to the module; the module is not operational.
Green
There is power to the module; the module is operating properly.
Red
There is an alarm condition.
Flashing Red
The module has detected a hardware/firmware fault.
Yellow
The module is undergoing configuration.