ACO6800
+
Installation and Operation Manual
55
Copyright © 2009, Harris Corporation
Chapter 5: ACO6800
+
DSD Parameters, LEDs, and Alarms
Main Device Alarms
These alarms are available in ASI and SDI modes.
Subdevice Alarms
describes the alarms for each of the subdevices on the
ACO6800
+
DSD. You can only identify specific alarms using a software control
application. Depending on which module you are using, some of the subdevice
alarms may not be available.
Trigger (s)
This option determines how long an alarm condition must exist (in
seconds) before the alarm is triggered. If the alarm level is reached
for less time than the
Trigger
duration, then the alarm will not
trigger. Choose any duration from 0 to 7200 (or 2 hours). If this
option is set to 0 and the alarm condition exists for any period of
time, the alarm will trigger.
Clear (s)
Determines the amount of time the alarm condition must be in
abate in order for the alarm to be turned off.
Choose any duration from 0 to 7200 seconds (or 2 hours). If this
option is set to 0 and the alarm condition ceases for any period of
time, the alarm will clear.
Ack
When an alarm is active, click here to allow other users on the
network to see that you have acknowledged the alarm.
Table 5-5. Alarm Options
Alarm Option
Effect
Table 5-6. Device Alarms For ACO6800
+
DSD Modules
Alarm Name
Priority
Trigger (s)
Clear (s)
Grp A Relay Bypass On
1
1.0 s
2.0 s
Grp B Relay Bypass On
1
1.0 s
2.0 s
Table 5-7. ACO6800
+
DSD Subdevice Alarm
Alarm Name
Alarm Description
Alarm Option Default Settings
Alarm
priority
Trigger (s)
Clear (s)
SDI Mode
SDI Video
Standard Mismatch
The standard video input does not
match the expected standard
1
2.0
2.0
SDI Loss of Video
Reports that active HD or SD video
has not been present
6
2.0
2.0
ASI Mode
ASI Error
Reports an ASI error (including ASI
loss) in streaming
1
1.0
2.0