ACO6800
+
Installation and Operation Manual
23
Copyright © 2009, Harris Corporation
Chapter 3: Configuration and Operation
Manual Control
When the switching is not triggered by other higher priority events, you can use
the parameters described in
to manually switch the source using either
CCS Navigator or the card-edge controls.
Table 3-3. GPI Input Control
GPI
Action/Result
GPI 1
Switches output source to IN 1
GPI 2
Switches output source to IN 2
Table 3-4. Manual Switch Parameters
Parameter Name
Bank,
Switch
Function
Options
ACO6800
+
ISD
Group A Manual Switch
1, E
Sets the output source when a channel is
switched manually
•
Disable
• Switch to A1
• Switch to A2
ACO6800
+
DSD and ACO6800
+
IDSD
Group A Manual Switch
1, E
Sets the output source when a channel is
switched manually
•
Disable
• Switch to A1
• Switch to A2
Group B Manual Switch
4, E
Sets the output source when a channel is
switched manually
•
Disable
• Switch to B1
• Switch to B2
ACO6800
+
ASID
Manual Switch
n/a
Sets the output source when a channel is
switched manually
•
Disable
• Switch to 1
• Switch to 2
ACO6800
+
ISCST
Manual Switch
1, E
Sets the output source when a channel is
switched manually
•
Disable
• Switch to A1
• Switch to A2