background image

Page 8 of 8 

 
 

 
 
 
 

 

 

Harrington Hoists, Inc. 

Harrington Hoists, Inc.  

401 West End Avenue 

2341 Pomona Rd  #103 

Manheim, PA  17545 

Corona, CA  92880 

Phone:  (717) 665-2000 

Phone:  (951) 279-7100 

www.harringtonhoists.com 

Certificate of 

Inspection and Test – Universal Beam Clamp 

 

This certifies that the following Harrington product: 

 

Conforms to the latest versions of ASME BTH-1, ASME B30.20 and ASME B30.16. 

 

Was thoroughly inspected. 

 

Was subjected to a static load test in accordance with the latest version of ASME  

B30.20. 

 
 

Code:  

Rated Capacity:   

Serial No.: 

 

Test Date: 

 

 

Load Applied: 

 

% of rated capacity 

 

Other/Remarks:  

   

 

 
 
 

 

 

 

Mark Miller 

 

 

 

 

 

      Chris Hess 

Quality Manager 

 

 

 

 

      Manager of Engineering 

 
 
 
 

 
 

 

Summary of Contents for UBC010

Page 1: ...related CAUTION These general instructions deal with the normal installation operation and maintenance situations encountered with the equipment described herein The instructions should not be interpr...

Page 2: ...0 83 0 83 1 00 1 00 1 75 Net Weight lbs 8 9 19 22 55 3 0 Preoperational Procedures 3 1 Mounting Location 3 1 1 WARNING When used as a suspension device ensure that the suspension and the supporting st...

Page 3: ...vice or an above the hoist suspending device Per the ANSI ASME B30 standards the use of a clamp is subject to certain hazards that cannot be mitigated by engineered features but only by the exercise o...

Page 4: ...vy Service Weekly to Monthly Semiannually Severe Service Daily to Weekly Quarterly Special or Infrequent Service As recommended by a qualified person before and after each occurrence As recommended by...

Page 5: ...sassembly and further inspection should only be performed by a qualified person trained in the disassembly and re assembly of the clamp 5 6 4 Periodic Inspection Disassembly of the clamp is required D...

Page 6: ...s determined there is no defect or that the defect resulted from causes not within the scope of Harrington s warranty the customer will be responsible for the costs of returning the product Harrington...

Page 7: ...Page 7 of 8 This Page Intentionally Left Blank...

Page 8: ...and Test Universal Beam Clamp This certifies that the following Harrington product Conforms to the latest versions of ASME BTH 1 ASME B30 20 and ASME B30 16 Was thoroughly inspected Was subjected to a...