GB 15
REGULATIONS
GB
Application
s !LLLOCALREGULATIONSINCLUDINGTHOSEREFERRINGTONATIONALAND%UROPEANSTANDARDSMUSTBEOBSERVEDWHENUSINGTHEAPPLIANCE
s %NSURETHATTHEREARENOCOMBUSTIBLEMATERIALSINTHEDIRECTVICINITYOFTHESTOVE
s +EEPTHESTOVECLOSEDEXCEPTWHENLIGHTINGANDADDINGFUELTOTHEAPPLIANCEANDWHENREMOVINGRESIDUALMATERIAL
s 0ARTSOFTHEAPPLIANCENOTABLYTHESURFACEAREHOTWHENTOUCHEDWHENTHEAPPLIANCEISBEINGUSED4AKEAPPROPRIATEMEASURES
s 5SElREWOODTHATISCMLONGANDCMTHICK0UTITmATONTHEBOTTOMOFTHESTOVE$ONOTPLACEMORETHANLOGSINTHESTOVEATTHE
SAMETIME7HENTHElRESTARTSTOGODOWNAFTERABOUTHOURADDWOOD
s $ONOTUSETHEAPPLIANCEASAMULTIBURNER$ONOTUSEFUELSTHATAREUNSUITABLEORNOTRECOMMENDEDANDINPARTICULARDONOTUSEANY
liquid fuels.
Maintenance
s (AVETHEAPPLIANCESERVICEDREGULARLYBYAQUALIlEDTECHNICIAN
s %NSURETHATTHEmUEGASCONNECTIONANDTHECHIMNEYARECLEANEDREGULARLY
s #HECKTOENSURETHATTHECHIMNEYISSTILLOPENBEFORELIGHTINGTHESTOVEAGAINIFITHASNOTBEENUSEDFORANEXTENDEDPERIODOFTIME
s )FINSPITEOFTHEPRECAUTIONSTAKENTHERESHOULDOCCURACHIMNEYlREUSUALLYACCOMPANIEDBYAROARINGNOISEINTHECHIMNEY PROCEED
ASFOLLOWS
- Shut off the air supply and close the door of the stove immediately
- Call the fire brigade
1UICKLYEXTINGUISHTHElREINTHESTOVEWITHSANDORSODATOPREVENTSMOKEFROMGETTINGINTOYOURHOUSE
- Ventilate the house
.EVERUSEWATERTOEXTINGUISHTHElRE
s %NSURETHATAFTERAlRETHECHIMNEYISlRSTSWEPTANDINSPECTEDFORANYDAMAGEANDLEAKS
Service
s )TISNOTALLOWEDTOMAKEANYMODIlCATIONSTOTHEAPPLIANCEWITHOUTPRIORAUTHORIZATIONOFTHEMANUFACTURER
s /NLYUSEREPLACEMENTPARTSRECOMMENDEDBYTHEMANUFACTURER
Declaration
4HEUNDERSIGNEDREPRESENTINGTHEFOLLOWING
(ARRIELEENDERS(AARDKACHELS)NDUSTRIEWEG$0/IRSCHOT.EDERLAND
HEREWITHDECLARETHATTHEPRODUCT&UGA-ISINCONFORMITYWITHTHEPROVISIONSOFTHEFOLLOWING%#$IRECTIVESWHENINSTALLEDINACCORDANCEWITHTHE
INSTALLATIONINSTRUCTIONSCONTAINEDINTHEPRODUCTDOCUMENTATION%.!% h2OOMHEATERSlREDBYSOLIDFUELv
0RODUCT2OOMHEATERSlREDBYSOLIDFUELSASCOVEREDUNDERTHESCOPEOFTHISSTANDARDINTENDEDUSE3PACEHEATINGINRESIDENTIALBUILDINGS
Characteristics
Report
&IRESAFETY
0-#
%MISSIONOFCOMBUSTIONPRODUCTS
0-#
2ELEASEOFDANGEROUSSUBSTANCE
0-#
3URFACETEMPERATURE
0-#
-ECHANICALRESISTANCETOCARRYACHIMNEYmUE
0-#
4HERMALOUTPUTENERGYEFlCIENCY
0-#
Description of the room heater Fuga M:
7OODSTOVEMADEOFSHEETMETAL4HESTOVEISDESIGNEDFORPLACEMENTONTHEmOORANDCANBEROTATED TOTHELEFTORTOTHERIGHT
)TISEQUIPPEDWITHASELFCLOSINGWINDOWDOORlXEDSECONDARYAIRSUPPLYANDCONTROLLABLEAIRWASHSUPPLY4HECOMBUSTIONCHAMBERIS
INSULATEDWITHCERAMIClREBRICKS4HEmUEGASCONNECTIONISLOCATEDATTHETOPOFTHEAPPLIANCE
.OTIlEDBODY4./)NDUSTRIEEN4ECHNIEK,AANVAN7ESTENENK0OSTBUS!(!PELDOORN
2EPORTNUMBER0-#
-ANUFACTURER(ARRIE,EENDERS(AARDKACHELS
.AME"ART,EENDERS
0OSITION'ENERAL-ANAGER
$ATE
Summary of Contents for FUGA M