Harrie Leenders Fuga M - Instructions for Installation, Use and Maintenance 

PREPARATORY WORK AND SAFETY CHECKS 

 

IMPORTANT WARNING 

 
This stove must not be installed into a chimney that serves any other heating appliance. 
 
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit 
fumes into the room. 
 

Chimney 

 
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate 
draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke problems into 
the room.  
 
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the 
top of the chimney should be satisfactory. Alternatively the calculation procedure given in EN 13384-1 may 
be used as the basis for deciding whether a particular chimney design will provide sufficient draught. 
 
The outlet from the chimney should be above the roof of the building in accordance with the provisions of 
Building Regulations Approved Document J. 
 
If installation is into an existing chimney then it must be sound and have no cracks or other faults which 
might allow fumes into the house. Older properties, especially, may have chimney faults or the cross sec-
tion may be too large i.e. more than 230 mm x 230 mm. Remedial action should be taken, if required, seek-
ing expert advice, if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid 
fuel must be used in accordance with Building Regulations Approved Document J. 
 
Any existing chimney must be clear of obstruction and have been swept clean immediately before installa-
tion of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month 
after installation to clear any soot falls which may have occurred due to the difference in combustion be-
tween the stove and the open fire. 
 
If there is no existing chimney then any new system must be to the designation described above and in ac-
cordance with Building Regulations Approved Document J. 
 
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for use as 
the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm 
and its dimension should be not less than the size of the outlet socket of the stove. 
 
Any bend in the chimney or connecting fluepipe should not exceed 45°.  90° bends should not be used. 
 
Combustible material should not be located where the heat dissipating through the walls of fireplaces or 
flues could ignite it. Therefore when installing the stove in the presence of combustible materials due ac-
count must be taken of the guidance on the separation of combustible material given in Building Regula-
tions Approved Document J and also in these stove instructions. 
 
If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted. Fitting 
of a draught stabiliser will affect the requirement for the permanent air supply into the room in which the 
stove is fitted in accordance with Approved Document J (see also combustion air supply). 
 
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney 
and connecting fluepipe where it is not intended for the chimney to be swept through the appliance. 

 

Summary of Contents for FUGA M

Page 1: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 1 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE FUGA M...

Page 2: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 2...

Page 3: ...or proper burning 12 The fine heat from wood 12 Initial fire up a good start 13 Initial fire up in steps 13 How to use the Fuga M 14 The power of fire 14 A few tips 14 Maintenance Ceramic firebricks 1...

Page 4: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 4 1 Door 2 Ceramic glass 3 Aeration slide 4 Base 5 Convection pipes 6 Convection fins 7 Door handle 8 Smoke baffle plate...

Page 5: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 5 Dimensions in mm...

Page 6: ...wing Harrie Leenders Haardkachels Industrieweg 25 5688 DP Oirschot Nederland herewith declare that the product Fuga M is in conformity with the provisions of the following EC Directives when installed...

Page 7: ...petent Persons can be found on their website at www hetas co uk CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a...

Page 8: ...be clear of obstruction and have been swept clean immediately before installa tion of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after instal...

Page 9: ...sion of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Connection to chimney Stoves may have...

Page 10: ...free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alar...

Page 11: ...supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade shou...

Page 12: ...w times do not make your fire too hot because otherwise the bricks could crack You need not worry about any shrinkage cracks The initial fire up requires some additional time and attention as well as...

Page 13: ...from the ceramic fire brick Therefore place an old towel underneath the stove before firing up 5 After an hour you will start bringing the entire stove to the proper temperature using first some thin...

Page 14: ...ing fire is obtained by closing the air slide even more by pushing it inwards This will reduce the draught in the Fuga M For a glowing mass of charcoal you may close the air slide even further The hea...

Page 15: ...e Thicker deposits These can be treated with special fireplace glass cleaner this can also be done with a piece of moist paper towel and white ash Allow a moment for this to have its effect Always mak...

Page 16: ...ply in the room from which your stove gets the combustion air This is the room where the stove is installed if you do not use a wall or stove base air supply system The stove is not suitable for a sha...

Page 17: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 17...

Page 18: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 18...

Page 19: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 19...

Page 20: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 20...

Page 21: ...Harrie Leenders Fuga M Instructions for Installation Use and Maintenance 21...

Page 22: ...Instructions for Installation Use and Maintenance 22 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www...

Reviews: