Harrie Leenders CANTA W Instructions For Installation, Use And Maintenance Manual Download Page 11

Harrie Leenders Canta ­ Instructions for Installation, Use and Maintenance 

11

 

Periods of Prolonged Non­Use

 

If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to 
remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce con­ 
densation and subsequent damage, leave the air controls fully open.

 

Extractor fan

 

There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit 
smoke and fumes into the room.

 

Aerosol sprays

 

Do not use an aerosol spray on or near the stove when it is alight.

 

Use of operating tools

 

Always use the operating tools provided when handling parts likely to be hot when the stove is in use.

 

Chimney Fires

 

If the chimney is thoroughly and regularly swept, chimney fires should not occur.  However, if a chimney fire 
does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly 
close the doors of the stove.  This should cause the chimney fire to go out. If the chimney fire does not go 
out when the above action is taken then the fire brigade should be called immediately. Do not relight the 
stove until the chimney and flue ways have been cleaned and examined by a professional.

 

Permanent air vent

 

The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. 
In accordance with current Building Regulations the installer may have fitted a permanent air supply vent 
into the room in which the stove is installed to provide combustion air. This air vent should not under any 
circumstances be shut off or sealed. 

USER OPERATING INSTRUCTIONS

 

Recommended fuels

 

Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the main 
stove manuals.

 

HETAS Ltd Approval

 

HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Approval 
does not cover the use of other fuels either alone or mixed with the recommended fuel, nor does it cover 
instructions for the use of other fuels.

Summary of Contents for CANTA W

Page 1: ...Harrie Leenders Canta Instructions for Installation Use and Maintenance 1 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE CANTA W...

Page 2: ...Harrie Leenders Canta Instructions for Installation Use and Maintenance 2...

Page 3: ...about the Canta 9 The three basic rules for proper burning 9 Warning note 10 Important notes 10 User operating instructions 11 The fine heat from wood 12 Initial fire up a good start 12 Initial fire...

Page 4: ...rrie Leenders Canta Instructions for Installation Use and Maintenance 4 1 Front 2 Ceramic glass 3 Aeration 4 Heat shield 5 Convection slots 6 Back casing 7 Sliding window 8 Aeration slide 9 Wall brack...

Page 5: ...owing Harrie Leenders Haardkachels Industrieweg 25 5688 DP Oirschot Nederland herewith declare that the product Canta is in conformity with the provisions of the following EC Directives when installed...

Page 6: ...petent Persons can be found on their website at www hetas co uk CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a...

Page 7: ...be clear of obstruction and have been swept clean immediately before installa tion of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after instal...

Page 8: ...ion of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Connection to chimney Stoves may have a...

Page 9: ...are subject to the greatest impacts being hit by wood when loading the fireplace and so have been additionally reinforced The air control slide controls the primary air flow over the fire and keeps t...

Page 10: ...free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alar...

Page 11: ...supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade shou...

Page 12: ...w times do not make your fire too hot because otherwise the bricks could crack You need not worry about any shrinkage cracks The initial fire up requires some additional time and attention as well as...

Page 13: ...an evaporate Some liquid might come free from the ceramic fire brick Therefore place an old towel underneath the stove before firing up 5 After an hour you will start bringing the entire stove to the...

Page 14: ...little bit until it is burning properly 5 A quietly burning fire is obtained by closing the air slide even more by pushing it inwards This will reduce the draught in the Canta For a glowing mass of c...

Page 15: ...fire always on a bed of ash This is an insulating layer for the fire and an excellent bed for the fuel If the Canta is overloaded with too much wood and the maximum amount of oxygen is supplied which...

Page 16: ...be treated with special fireplace glass cleaner this can also be done with a piece of moist paper towel and white ash Allow a moment for this to have its effect Always make sure that these agents do n...

Page 17: ...land at the bottom of the stove 1 Slightly lift the ceramic baffle and pull it towards you You can then take it out easily Then lift the steel baffle to remove it 2 Place a newspaper on the bottom of...

Page 18: ...s installed if you do not use a wall or stove base air supply system The stove is not suitable for a shared flue system Ensure adequate access for cleaning the appliance the flue gas connection and th...

Page 19: ...manufacturers on a 3m straight flue Safety recommendations Glass tends to break easily and broken glass is quite sharp Therefore take adequate safety precautions For general safety we refer to guidel...

Page 20: ...the bolts Place the stove including the MTI brace on a sack truck back of stove against the sack truck 2 Ceiling or wall plate Fasten the ceiling or wall plate using the plugs and stucco screws provid...

Page 21: ...ket head bolts provided at the back of the wall support to level the stove depth wise Tap the pins into place 5 Hanging the stove Place sliding pieces underneath the transport brace Push the stove aga...

Page 22: ...arefully over the stove without damaging the paint Position the jacket into the right position if necessary by means of the 2 M6 bolts on both sides of the stove 11 Installing flue Push up the smoke o...

Page 23: ...window frame is attached Now the window can be pushed up 15 Adjusting the glass pane if necessary The glass pane should lean slightly backwards it is lightly biased against the rope seal at the top In...

Page 24: ...Harrie Leenders Canta Instructions for Installation Use and Maintenance 24...

Page 25: ...Harrie Leenders Canta Instructions for Installation Use and Maintenance 25...

Page 26: ...Instructions for Installation Use and Maintenance 26 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www r...

Reviews: