![Harol S1 Installation And User Manual Download Page 23](http://html1.mh-extra.com/html/harol/s1/s1_installation-and-user-manual_3968147023.webp)
03/2019
23
GB
a) Heat regulation:
Switching on/off:
Brief pressing of the programmed wireless channel button
on the hand-held transmitter switches the connected radi-
ant heater on or off.
Short-term heating:
Double-clicking the programmed wireless channel key
switches the radiant heater on for 15 minutes and then
automatically switches it off again.
Heating level:
Extended pressing of the programmed key on the hand-
held transmitter switches the heat output up and down
between three levels (33, 66 and 100%).
Memory function:
Upon switching back on, a short press of the key recalls
the last heating level.
Timed switch off:
If a timed switch-off has been activated in the program-
ming, the radiant heater always switches off automatically
after the specified time. The radiant heater signals as fol
-
lows after the activating the set residual run time:
Signal duration 2s - 30 minutes residual run time
Signal duration 4s - 60 minutes residual run time
Signal duration 6s - 90 minutes residual run time
Synchronisation:
If multiple radiant heaters are controlled using the same
hand-held transmitter button, faults in the wireless trans-
mission path can result in different states. For synchroni-
sation, use the function „Heating level“ to initially set all
radiant heaters in switched-on state. Then switch off all
receivers by a briefly pressing the key. The „Heating level“
function can now be used to simultaneously set again all
the actuated receivers.