background image

 
 
 

P-G 400/4 - 18.04.2013 / Vers.: 1

 

9

 

The blasting chamber illumination is activated when the main switch is switched on: 

1.  by pressing one of the keys (5) or 

2.  by pressing the pedal switch or 

3.  by withdrawing one of the blasting stylusses (31) from the holder (44). 

The  blasting  chamber  illumination  remains  switched  on  for  as  long  as  a  blasting  stylus  is 
withdrawn. 

The vacuum extraction switches on automatically by actuating the pedal switch while the main 
switch  is  switched  on  and  a  blasting stylus is withdrawn. The vacuum extraction switches off 
after approximately 7 seconds if the pedal switch is no longer actuated (the time can be set). 

3.6  Activating the desired blasting system (automatic recognition) 

(see Fig. 2 page 5 and Fig. 4 page 8) 

 

1.  All  blasting  styluses  (31)  must  be  inserted  in  the  blasting  stylus  holders  (44)  according  to 

their color marking. 

2.  By  removing  the  desired  blasting  stylus  from  the  blasting  stylus  holder,  the  corresponding 

blasting system is automatically activated. 

3.  The  operating  parameters  (dosing  the  blasting  agent  amount  and  operating  pressure),  as 

adjusted during last use of this blasting system, are taken over and indicated in the display 
(10). 

4.  The sand blast is activated with the foot pedal. 

   

Attention 

If  the  front  cover  (40)  or  the  cover  (23)  of  the  blasting  agent  container  chamber  is  not 
completely closed, the sand blast cannot be activated. After activating the foot pedal "

Close 

cover

” is indicated in the display (10). 

   

5.  Before a new blasting system can be activated, the blasting stylus previously removed must 

be put back in the blasting stylus holder. 

   

Remark 

The respectively active blasting system is indicated with the control lights in the push buttons 
(5/...) of the relevant operating field. 

   

Remark 

If  all  blasting  styluses  (31)  are  removed  from  the  blasting  stylus  holders  (44),  the  desired 
blasting  system  can  be  activated  with  the  push  buttons  (5/...).  See  "3.11.6   and   7  LED-
Display”. 

3.7  Adjusting the operating pressure (blasting pressure) 

(see Fig. 4 page 8) 

 

  The  operating  pressure  is  set  separately  for  each  blasting  system  with  the  corresponding 

operating  pressure  regulator  (9)  and  is  indicated  in  bar  in  the  display  (10),  see  section 
"3.11.5”).  The  relevant  setting  is  maintained  for  the  blasting  system  concerned  until  it  is 
changed. 

Depending  on  the  requirements,  it  is  possible  to  work  with  0.5  bar  to  7  bar.  Normally,  a 
maximum operating pressure of 5 bar is sufficient. 

Also observe pre-pressure regulator setting, see 3.2.2 

3.8  Dosing the blasting agent amount 

(see Fig. 4 page  8) 

 

The  blasting  agent  portion  in  the  spot  blast  of  the  relevant  activated  blasting  system  is 
adjusted with the push buttons (6) and (7) and indicated in the LED display (10) with "

Volume

and a figure from "

0

" to "

9

". 

    value "

0

” means minimum of blasting agent portion 

    value "

9

” means maximum of blasting agent portion 

Summary of Contents for P-G 400/4

Page 1: ...nation Spot blasting unit Machine type P G 400 4 Machine no Keep for future reference Hausanschrift Harnisch Rieth GmbH Co KG K ferstr 14 16 D 73650 Winterbach Telefon 49 7181 96 78 0 Telefax 49 7181...

Page 2: ...unit to the necessary exhaust unit 6 3 2 Connecting the spot blasting unit to the compressed air supply 6 3 3 Filling the blasting agent into the blasting agent container 7 3 4 The blasting systems a...

Page 3: ...s Never use the blasting stylus outside the protective blasting chamber i e do not lead the blasting hose out of the unit Never look into the installed blasting nozzle or into the blasting hose withou...

Page 4: ...6 Identification of the safety remarks in this manual Remark Indicates application tips and other particularly useful information Attention Indicates operating or handling measures which can lead to...

Page 5: ...e regulator for adjusting the jet pressure with digital display f Automatic Reserve level indication with digital display Fig 1 View of unit from front left hand side 4 1 Blasting agent container whit...

Page 6: ...ng of blasting agent amount see section 3 8 5 A T 1 A T 8 A T I 0 23 2725 15 16 21 40 41 36 31 44 22 4246 48 43 49 K ferstr 14 16 73650Winterbac h Harnisch Rieth Made in Germany Maschinen Typ Maschine...

Page 7: ...lid supplied 2 Connect exhaust unit to power supply connector 17 230V Maximum electrical connection value 1000 Watt 3 Please observe the operating manual of the exhaust unit Remark We recommend using...

Page 8: ...nt screws 8 are to be opened in general Thus the pressure in the blasting agent containers can escape and the wing screw 25 is relieved 3 Open wing screw 25 until stirrup 27 can be swung to the side 4...

Page 9: ...EW 60 250 m 1 0 mm 1 2 mm red 1 0 mm special polish blasting medium aluminium oxide Cl 60 B 120 m Cl 150 A 150 m 0 8 mm 1 0 mm Attention The unit has been designed for the use of H R blasting agents...

Page 10: ...er chamber is not completely closed the sand blast cannot be activated After activating the foot pedal Close cover is indicated in the display 10 5 Before a new blasting system can be activated the bl...

Page 11: ...hortly The display shows Blasting time Select the desired time sec with keys 6 or 7 sec Value 0 sec no beep Remark After termination of the blasting time selected blasting is not interrupted automatic...

Page 12: ...ting agent container Reserve and Volume appear alternating see 3 9 3 Bottom left Blasting agent type e g ALOX see 3 9 a page 10 4 Bottom middle Blasting agent grain size m see 3 9 b page 10 5 Bottom r...

Page 13: ...isconnecting the quick coupling 62 Ventilate all blasting agent containers by opening the vent screws 8 and subsequently fastening them again 1 Unscrew swivel nut 30 from blasting stylus sleeve 56 and...

Page 14: ...7 Extract securing bolt from base 22 8 Pull out base 22 downwards from the clamping cylinder housing 46 9 Unscrew cover sheet 59 10 Remove blasting hose 26 downwards from the clamping cylinder housin...

Page 15: ...ring 26 Blasting hose 38 Diverting cap 29 Blasting chamber 39 Blasting chamber sheet 30 Swivel nut 45 Holding bolt 32 Blasting nozzle 46 Clamping cylinder housing 33 Hose bushing 47 Spring plug 34 Rub...

Page 16: ...Insert blasting hose tightly into the blasting stylus sleeve see Fig 8b 10 Slide diverting spring 37 and diverting cap 38 on the blasting hose as shown in Fig 8b 11 Push blasting hose from the blastin...

Page 17: ...Dimensions width 490 mm with plug for foot pedal depth 680 mm with quick coupling height 400 mm with vent screws Electrical connection 230 Volt 50 Hz Over voltage category II Compressed air supply max...

Page 18: ...parties 7 Unit breakdown resulting from adjustment alteration or any other attempt to adapt the unit is not considered a material or production fault This guarantee neither encompasses the costs of su...

Page 19: ...7 EMC directive 2004 108 EG 20 07 2007 Following harmonizing standards were applied DIN EN ISO 12100 Safety of Machinery Part 1 General Principles of Design 04 2004 DIN EN ISO 14121 1 Safety of Machin...

Reviews: