This manual contains all the necessary information for installation, error messages, 
discharge and maintenance. Read the manual carefully before you open the unit. The 
manufacturer of this product will not be held responsible for injuries or damage to the 
product resulting from an incorrect installation, discharge or unnecessary 
maintenance. It is essential that the instructions in this manual are always followed 
carefully. Qualified personnel must install this product. 

 

 

Only a qualified installer, center, personnel or a recognized dealer may repair this 
product.  
 

 

Maintenance and service must respect the recommended time and frequency, as 
mentioned in the manual.  
 

 

Only use the original spare parts. Failure to do so will void the warranty. 

 

Characteristics

 

 

 

Durability: The most frequently used products are chlorine, acid (sulfuric acid) and 
base resistant.  These can resist long‐term exposure to swimming pool water (even 
with salt for salt electrolysis). These peristaltic pumps are not to be used with 
sulfuric acid (HCI) 
 

 

Easy‐use: The unit is very easy to use: Turn it on and set the pH (acid) or redox value 
(chlorine).  

 

 

Low cost: With correct use the swimming pool water will never turn green, keeping 
operational costs low. 

 

 

 

 

Summary of Contents for ZWMX7510-P

Page 1: ...Geassembleerd door Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek Belgi www harmopool eu Microdos Pool twin watertreatment on plate ZWMX7510 P...

Page 2: ...Table of contents Introduction 3 Specifications 4 Installation 5 Installation items 5 Installation of the water treatment plate 6 Winter ready 8 Spring startup 8 Maintenance 9 Warnings 9...

Page 3: ...r center personnel or a recognized dealer may repair this product Maintenance and service must respect the recommended time and frequency as mentioned in the manual Only use the original spare parts F...

Page 4: ...4 Specifications ZWWX7510 P pH regulation Microdos Speedy pH Chlorine regulation Microdos Speedy Chlorine Pool connection 50mm rubber Flow switch safety Optional Plate measurements 50 x 50 cm...

Page 5: ...ommended to set the water treatment unit to bypass mode Install the water treatment unit on a stable platform Always keep the unit straight If the unit has been tilted or placed on its side the electr...

Page 6: ...then past the dispenser caps If the water in the unit is heading the opposite way simply unclick the measurement and dispenser tubes turn them around and reclick Bypass configuration is preferred 3 C...

Page 7: ...n PH will be set to 7 4 and redox at 700 mV After the primary startup measure the pH and chlorine levels with a color method Change the set point for redox if necessary lower if chlorine levels are to...

Page 8: ...The tube is at the end of its life with chemical compatibility after 500 600 hours of performance B Determination of incompatible products with the Santoprene material of the tube PH regulation with...

Page 9: ...hey leak o Check the power supply and cable connection frequently If the pump starts functioning abnormally disable it and call a technician Warnings Incorrect installation can cause a chemical or ele...