Harmopool ZVWX4013 Instructions Manual Download Page 12

 

 

 

12 

 

Spring start-up 

If your heat pump has been winterized, perform the following steps when starting the 
system in the spring: 
 
1. 

Inspect the system for any debris or structural problems. 

2. 

Connect the water inlet and outlet unions firmly. 

3. 

Turn on the filter pump to supply water to the heat pump.  Adjust the by-pass to 
allow water flow through the heat pump. 

4. 

Turn on the electrical power to the heat pump at the main breaker panel. 

Owner inspection 

The ECO heat pumps are designed and constructed to provide long performance life when 
installed and operated properly under normal conditions. Periodic inspections are 
important to keep your heat pump running safely and efficiently through the years. The 
following basic guidelines are suggested for your inspection: 

 

1. 

Make sure the front of the unit is accessible for future service. 

2. 

Keep the surrounding areas of the heat pump clear of all debris. 

3. 

Keep all plants and shrubs trimmed and away from the heat pump. 

4. 

Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion 
and damage.  Use a deflector if needed. 

5. 

If the unit is installed under a very sharp roof pitch or under a roof without a gutter, 
a gutter or diverter should be fitted to prevent excessive water from pouring down 
onto the unit. 

6. 

Do not use the heat pump if any part has been under water. Immediately call a 
qualified professional technician to inspect the heat pump and replace any part of 
the control system, which has been submerged. 

 

The heat pump will produce condensation (water) while in operation. The heat pump base 
is designed to allow the condensation to exit through the bottom drain port. The 
condensation will increase as the outdoor air humidity level increases. Check the following 
at regular intervals to ensure proper condensate drainage: 
 
1. 

Visually inspect and clear the bottom drain port of any debris that could clog the 
port. 

2. 

Keep the air intake area and discharge area clear of debris so the airflow through 
the heat pump is not restricted. The cooler discharge air should not accumulate and 
be drawn into the side air intake coils. 
During normal operation, the heat pump produces ten to twenty liters of 
condensate per hour. If condensate drainage is above this range during operation 
or if water continues to drain from the base when the heat pump is not in 
operation for more than an hour, a leak in the internal plumbing may have 
occurred.  Call a qualified heat pump technician to investigate the problem. 

 

Attention!

 A quick way to verify that the water running through the drain is condensation 

water is to shut off the unit and keep the pool pump running. If the water stops running 
out of the base pan, it is condensation water.  
 

 

Summary of Contents for ZVWX4013

Page 1: ...Imported by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www harmopool eu Swimming pool heat pump Instruction manual ECO series Type ZVWX4013 ZVWX4023 ZVWX4033 ZVWX4053 ...

Page 2: ...istance 7 Installation of the valve 7 Configuration 7 Installation of the bypass 8 Electrical wiring 9 Start up procedure 10 Daily use of the heat pump 10 Condensation 10 Guidelines 11 Water chemistry 11 Winter ready 11 Spring start up 12 Owner inspection 12 Maintenance and inspection 13 Maintenance 13 Warnings 13 Problems and solutions 14 Checklist 15 Warranty 16 ...

Page 3: ...el or an authorized dealer can only repair the unit Maintenance and operation must be carried out according to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will void warranty Characteristics Durable the heating exchanger is made of PVC Titanium tube which can withstand prolonged exposure toswimming po...

Page 4: ...pressor rotary rotary rotary rotary Refrigerant R407C R407C R407C R407C Refrigerant quantity Kg 0 5 0 8 1 0 1 3 Fan quantity 1 1 1 1 Fan Power Input W 20 25 25 30 Fan Speed RPM 950 900 900 890 Fan Direction horizontal horizontal horizontal horizontal Noise at 2m dB A 51 54 55 57 Water Connection mm 50 50 50 50 Nominal Water Flow m3 h 3 5 4 6 4 7 4 7 Water Pressure Drop max kPa 10 10 12 15 Unit Net...

Page 5: ...imensions of the heat pump A B C D E F G H ZVWX4013 213 293 770 810 80 200 455 485 ZVWX4023 280 360 936 970 80 200 521 551 ZVWX4033 280 360 936 970 80 200 521 551 ZVWX4053 301 370 1010 1050 83 270 585 615 ...

Page 6: ...been tilted or put on his side allow 24h before starting the unit The unit may be installed virtually anywhere outdoors For indoor pools please consult your supplier Location The unit may be installed virtually anywhere outdoors For indoor pools please consult your supplier DO NOT put the unit in an enclosed area with a limited air volume where the unit discharge air will bere circulated DO NOT pu...

Page 7: ...ement of injectors of chemicals are very important aspects of the installation All addition of chemicals have to be done downstream from the heat pump Failure to protect the heat pump unit from chemical damage is not covered by your warranty A check valve must be installed between the heat pump and the chemical feeder to prevent back siphoning of chemically saturated water into the heat pump where...

Page 8: ...our heat pump will deliver its best performance The bypass has to be built as shown below Setting the valves of the by pass Install the bypass with all 3 valves entirely open Slightly close valve 1 Close valve 3 about half way to adjust the refrigerant pressure ...

Page 9: ...heat pumps require a single phase connection Earthing the heat pump is required to protect you against electrical shocks caused by an eventual short circuit inside the heat pump Values in this table are only guidelines Please check your local regulations The heat pump is not equipped with a flow switch or any other kind of water flow detection Therefore the heat pump has to be wired electrically t...

Page 10: ...r chatter This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption Even a brief power interruption will activate this delay and prevent the unit from starting until the 3 minute countdown is completed Daily use of the heat pump The heat pump can be switched on an off via the on off switch The heat pump can also be connected to the same power grid ...

Page 11: ... pump A check valve must be installed between the heat pump and the chemical feeder to prevent back siphoning of chemically saturated water into the heat pump where it will damage the components Winter ready Attention Failure to winterize could cause damage to the heat pump and will void warranty In areas where freezing temperatures occur you should protect your pump filter and heat pump from the ...

Page 12: ...ouring down onto the unit 6 Do not use the heat pump if any part has been under water Immediately call a qualified professional technician to inspect the heat pump and replace any part of the control system which has been submerged The heat pump will produce condensation water while in operation The heat pump base is designed to allow the condensation to exit through the bottom drain port The cond...

Page 13: ...charge all water from the water pump and other systems to prevent damage from freezing o You should discharge the water at the bottom of the heat pump if the unit will not work for an extended period of time You should check the unit thoroughly and fill the system with water fully before using it for the first time after a prolonged period of no usage Warnings Improper installation will create an ...

Page 14: ...ure setting 5 Bypass wrong adjusted 5 Adjust bypass as shown in manual 6 No gas pressure 6 Call your technician 7 Time delayed operation 7 Wait 3 min for heat pump to start 8 Air temperature below 12degC 10 C 8 Wait until temperature has risen No sufficient heating 1 Obstacles blocking air flow 1 Increase access of fresh air 2 Ice on the evaporator 2 Turn heat pump off too cold air 3 By pass wrong...

Page 15: ...15 Checklist ...

Page 16: ...16 Warranty ...

Reviews: