Distance 

Install the heat pump as close to the swimming pool as possible to minimize the loss of heat through the piping. 
Put it on a solid base and place some rubber blocks under the heat pump to eliminate vibrations.  
 
Normally, the heat pump is installed within a 7,5 meter radius of the pool. Heat loss is minimal up to distances of 

30 meters. The heat loss per 30 meters is estimated at 0.6kw/hour for every 5˚C difference between the pool 

water and surrounding of the pipe.  This increases the lifespan around 3-5%. 
 

Installation of the valve 

The placement of the chlorinator, water balance equipment, and the placement of injectors of chemicals, are very 
important aspects of the installation. All addition of chemicals have to be done downstream from the heat pump. 
Failure to protect the heat pump unit from chemical damage is not covered by your warranty. A check-valve must 
be installed between the heat pump and the chemical feeder to prevent back-siphoning of chemically saturated 
water into the heat pump where it will damage the components. 
 

 

Summary of Contents for Harmo PAC Series

Page 1: ...rted by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek Belgi www harmopool eu Swimming Pool Heat pump Instruction manual Harmo PAC series Type ZVWX1017 ZVWX1023 ZVWX1033 ZVWX1042 ZVWX1052 ZVWX1057 ZVW...

Page 2: ...5 Distance 6 Installation of the valve 6 Installation of the pool system 7 Installation of the bypass 7 Electrical wiring 8 Start up procedure 9 Condensation 9 Guidelines 9 Water chemistry 9 Winter r...

Page 3: ...ater temperature Silent operation the intelligent LCD display allows you to set the perfect temperature Low cost the operational cost is very low compared to the high performance of this heat pump Saf...

Page 4: ...10 10 10 Heating Capacity kW 27 air 27 water 7 0 12 0 14 0 19 0 23 0 23 0 28 0 Nominal power consumption A 5 1 7 3 9 5 13 1 16 10 5 12 4 Nominal water flow rate m h 3 to 5 5 to 7 6 to 8 8 to 10 10 to...

Page 5: ...ide basis en gebruik de dempende rubber om het geluid en de vibratie te elimineren Keep the unit straight up at all times When the unit has been tilted it is required to wait 24 hours before re starti...

Page 6: ...nce between the pool water and surrounding of the pipe This increases the lifespan around 3 5 Installation of the valve The placement of the chlorinator water balance equipment and the placement of in...

Page 7: ...set correctly your heat pump will deliver its best performance The bypass has to be built as shown below Setting the valves of the by pass Install the bypass with all 3 valves entirely open Slightly...

Page 8: ...he heat pump together with the proper wiring characteristics The current to the heat pump should only be applied when the filter pump is running For example a relay controlled by the filter pump could...

Page 9: ...ng and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption Even a brief power interruption will activate this delay and preven...

Page 10: ...t pump 4 Turn on the electrical power to the heat pump at the main panel Owner inspection The HARMO PAC heat pumps are designed and constructed to provide long performance life when installed and oper...

Page 11: ...shut off the unit and keep the pool pump running If the water stops running out of the base pan it is condensation water Display settings 1 Under running status press to adjust the temperature 2 Press...

Page 12: ...tection cooling mode setting press to alter Press SET again to confirm Press M again E 40 Press SET to enter Max temp setting press to alter Press SET again to confirm Press M again F 2 Press SET to e...

Page 13: ...able o Under parameter setting press to set data o Please note no motion on the display for 10s the LCD will display water in water out temp under running or ambient temp under standby status o Under...

Page 14: ...14...

Page 15: ...filter o The area around the heat pump should be dry clean and well ventilated Clean the heat exchanger regularly to maintain a good heat exchange and to save energy o Only a certified technician shou...

Page 16: ...16 Appendix wiring diagram Model ZVWX1017 ZVWX1023...

Page 17: ...17 Model ZVWX1033...

Page 18: ...18 Model ZVWX1042 ZVWX1052...

Page 19: ...19 Model ZVWX1052 ZVWX1062...

Reviews: