Chapter 2 Initial Configuration and Basic Opera-
tion
© 2013 Harmonic Inc. Harmonic All rights reserved.
24
Ellipse 3000 Release 3.0, Rev. B
Web Configuration
Once initialization is complete and the web manager displays, you can set up the system. For
details on web manager operations, see
NOTE:
When accessed from remote using the web, there is a print: “remote http connection”. If there are
several simultaneously http connections, there is a print: “multiple http connection”.
2.1.1
Encoder and Modulator Status Monitoring
The Ellipse Status display enables the monitoring of the encoder streams’ parameters and the
current rate and operation mode of the modulator parameters.
For Ellipse 3200 DSNG model displays the configured Modulation and Carrier operation mode (on
or off) as well as the Symbol Rate and TX Frequency rates of the modulator.
NOTE:
Although a DSNG unit can be equipped with either an IF modulator or an L-Band modulator, the
information displayed is generic and the parameters do not change; the only difference is in the values and
ranges. For an IF Up-Convertor, the screen specifies the IF Frequency value instead of TX Frequency value, given
for L-Band Modulator.
2.1.1.1
Front Panel Monitoring
To monitor the Modulator Status on the front panel, check the Ellipse Idle screen (see the
following example for IF Up converter information).
V1: rate4.620 resF720
Status OK
V2: rate4.620 resF720
Modulation: Y * Carrier: N
Symbol Rate: 10000000 sps
Press Enter for menu
IF Frequency: 700000 kHz