| www.harmar.com |
P 800-833-0478
6
© 2014 Harmar, LLC • All Rights Reserved
Troubleshooting
TROUBLESHOOTING
If your lift does not operate, diagnose the problem
by listening to the beeps emitted:
• A long beep when the control switch is
pressed indicates the lift is touching an
obstruction.
• One beep per second for 30 seconds (after
a 30 second delay) indicates the lift has
been stopped off the charge station. It is
recommended that the lift be immediately
moved to a charge station (located either end
of the rail).
• Two beeps every 60 seconds indicates a major
fault with the circuit board. Turn unit off and
back on to reset.
• Three beeps every 60 seconds indicate a major
fault with the footrest sensor. Turn unit off and
back on to reset.
• Seven beeps every 60 Seconds indicate a
major fault with the slow down switches. Turn
unit off and back on to reset.
• Eight beeps every 60 seconds indicate a major
fault with the limit switch. Turn unit off and
back on to reset.
If your lift fails to reset, contact your dealer for
service.
NOTE:
A fault is defined as major any time it requires
the unit to be turned off and back on to reset.