Helix Curved Stair Lift - Install and Service Manual 2016
9
TEC0067 P/N: 630-00063-01 Rev B
11.
Replace Shroud and install load switch cover on back.
Test run chassis
to ensure all the clearances are ok. Move rail as needed to make the best fit. If
installing mid-charging location locate it now.
Installing Mid-Charge Locations
1) Locate Chassis to where the midstation park should be on the rail.
[Figures 9-1, 9-2]
2) Mount to the rail using self taping screws provided
[Figures 9-3, 9-4]
3) Align charge feet to chassis, ensure the charge feet are compressing about 1/4".
[Figures 9-5, 9-6, 9-7]
4) Drill the hole in the rack to pull
wire out.
[Figure 9-8]
5) Connect wire to charge station,
ensure the red wire matches the
location of the red wire on the
chassis.
[Figure 9-9]
6) Install Cover
INSTALLATION
Figure 9-1
Figure 9-2
Figure 9-3
Figure 9-4
Figure 9-5
Figure 9-6
Figure 9-7
Figure 9-8
Figure 9-9
The unit will stop on this when driven with the wireless remote. It will stop for 5 to 6 seconds then continue.