Harman Soundweb London BSS BLU-120 Installation Manual Download Page 8

2

Front Panel 

Input Card Monitoring

Each channel has 3 LED indicators showing:

• Clip

Illuminated–Indicates clipping in the analogue domain for each channel of the 

fitted Input or Output card. The LED will illuminate at +18.5dB.

• Signal

Illuminated–The Signal LED will illuminate for each channel of a fitted Input or 

Output card when the signal reaches or exceeds the signal threshold of -20dB�

• Sync/48V

Illuminated–Illuminates to in48V phantom power has been activated 

for the relevant channel of a fitted input card. Also indicates sync status for 

digital I/O card�

Conductor [BLU-800/BLU-320/BLU160/BLU-120] 

Master [BLU-805/BLU-806 (DA)/BLU-325/BLU-326 (DA)]

The master clock device of a CobraNet

TM

 system is referred to as the Conductor–

the CM-1 modules in the system auto-negotiate which device will transmit the 

Conductor beat packet� The LED illuminates to indicate which device is acting 

as the Conductor� The master clock device of an AVB or Dante™ system is 

indicated with a Master LED on the front panel of the device that is providing 

the master clock function�

Network Link

The Network Link indicates the presence of Cat 5 Ethernet cables� If no 

cables  are  connected,  the  LED  is  unlit;  the  LED  flashes  if  either  a  control 

or CobraNet

TM

/AVB/ Dante™ cable is fitted and remains illuminated if both 

cables are connected�

Data Activity

The Data Activity LED will flash to indicate that the device is communicating 

with another control device, either on the network or via the serial or control 

ports�

LCD Display

Top line Indicates device name and run state� Bottom line indicates Time, IP Address, Subnet Mask, and Model 

number with firmware version. Also, the device’s MAC Address can be viewed by powering the device on whilst 

pressing and holding the Locate switch�

LOCATE

Pressing the Locate switch on the front of 

the unit will illuminate the Locate switch 

on the rear and identify the device within 

London Architect� Similarly the switch will 

illuminate if the device is selected from 

within London Architect or from the Locate 

switch on the rear�

Contrast (Hold)

Pressing and holding the Locate switch will cycle the LCD through its contrast range�

Summary of Contents for Soundweb London BSS BLU-120

Page 1: ...Soundweb TM London BLU 800 BLU 805 BLU 806 BLU 806DA BLU 320 BLU 325 BLU 326 BLU 326DA BLU 160 BLU 120 Installation Guide 5086087 A...

Page 2: ...ude use do not use this product above 2000m WARNING FOR YOUR PROTECTION READ THE FOLLOWING READ THESE INSTRUCTIONS KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS DO NOT USE THIS APP...

Page 3: ...s with the requirements of the Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU RoHS Directive 2011 65 EU WEEE Directive 2012 19 EU With regard to Directive 2005 32 EC and EC Regulation 1275...

Page 4: ...RE S CURIT LIRE ATTENTIVEMENT LIRE CES CONSIGNES CONSERVER CES CONSIGNES RESPECTER TOUS LES AVERTISSEMENTS SUIVRE TOUTES LES CONSIGNES NE PAS UTILISER CET APPAREIL PR S DE L EAU NETTOYER UNIQUEMENT AV...

Page 5: ...ITETT V SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN APPARATET SKAL TILSLUTTES JORDET STIKKONTAKT D CLARATION DE CONFORMIT Nom du fabricant BSS Audio Adresse du fabricant 10653 S River Front Parkway S...

Page 6: ...TE 2 Contrast Hold 2 Rear Panel 3 AC Mains 3 CobraNetTM Connectors Primary Secondary BLU 800 BLU 320 3 AVB BLU 805 BLU 325 3 DanteTM AES67 BLU 806 DA BLU 326 DA 3 BLU link 3 Locate 4 RS232 4 Ethernet...

Page 7: ...USA BY BSS AUDIO RS232 LOCATE S S S S S S S S S S S S S S S S WORDCLOCK T1 6AH 250V FUSE 100 240V 50 60Hz 55W CobraNet BLUlink IN OUT If the unit is likely to undergo extreme vibration through extens...

Page 8: ...ith a Master LED on the front panel of the device that is providing the master clock function Network Link The Network Link indicates the presence of Cat 5 Ethernet cables If no cables are connected t...

Page 9: ...nabled It will be enabled in a future release of HiQnet London Architect The physical AVB connections must be made using Cat 5e cables and an AVB compatible network switch See Technical Specifications...

Page 10: ...d operate as a redundant pair A 48kHz system clock is generated at the BNC OUT port when used in this fashion If Box B ceases to receive the 48kHz system clock from Box A due to power failure of Box A...

Page 11: ...12 control inputs and two software assignable reference voltage outputs R to the right The control ports have two modes of operation 2 wire and 3 wire 2 Wire Mode In this mode the 12 control inputs a...

Page 12: ...LED relay When sourcing from the Logic Output an LED connected between one output Anode A and common Cathode K will illuminate when the logic output is activated without requiring any external current...

Page 13: ...electronically balanced on Phoenix Combicon removable screw connectors MIC LINE INPUTS Nominal gain 0dB electronically switchable up to 48dB in 6dB steps INPUT IMPEDANCE 3 5kOhm MAXIMUM INPUT LEVEL 2...

Page 14: ...ctor for failsafe control OPTO OUTPUT CURRENT 14mA maximum WITHSTANDING VOLTAGE 80V maximum Off SERIES IMPEDANCE 220 Ohms isolated CONTROL NETWORK CONNECTORS RJ45 Ethernet connector MAXIMUM CABLE LENG...

Page 15: ...ical fans have a limited life expectancy We recommend annual inspection of fans for dust occlusion and excessive noise Fan assemblies should be replaced after six to ten years of use Environmental fac...

Page 16: ...Phone 801 566 8800 Website bssaudio com Support bssaudio com en US support BSS Audio is a registered trademark of HARMAN 2017 HARMAN All rights reserved Printed in Malaysia...