INSTAllATION

wArNINg:

 This stove must be installed in accor-

dance with all state and local building code require

-

ments.

locating the stove

Locate the stove as close to the chimney or flue as 

possible, while still maintaining the clearances to com

-

bustibles.

Locate the stove where there is sufficient air supply for 

ventilation and proper combustion.

Clearance to Combustibles

Safe stove clearance to combustible walls is 24” to 

the rear and 36” to the sides and front. Do not place 

furniture and the like directly in front of the stove. 

Floor Protection

Floor protection for a combustible floor should con

-

sist of 3/8” millboard or a stove board providing equal 

protection(k=.84, R=.45). The floor protection should 

extend 8” to the rear and either side and 6” in front of 

the stove. The floor protection should also extend 2” to 

either side of the chimney connector, to the wall where 

the connector enters the flue.

 36”

  8”

 36”

  8”

  8”

 16”

 24”

Floor Protection

Floor Protection

Adjustable leveling Feet

To accomodate an un-even hearth surface, the SF250 

is equipped with adjustable leveling feet. Each foot 

can be turned in or out of the leg to lower or raise that 

corner of the stove.

Turn the round foot in or out to 

level each corner of the stove.

It is recommended that you have your unit installed 

and serviced by professionals who are certified by the 

National Firplace Institute (NFI) as NFI Specialists.

Summary of Contents for SF 250

Page 1: ...MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authorit...

Page 2: ...Table of Contents Safety Considerations 3 Assembly 4 Installation 5 Chimney Venting 6 Operating Instructions 8 Preventive Maintenance 9 Optional Hot Water Coil 10 Testing Label 12 Warranty 13...

Page 3: ...rate It has been verified that creosote will ignite at 650 degrees fahrenheit It is the owner s responsibility to follow these recommenda tions This stove consumes air when it is burning if your house...

Page 4: ...The shaker handle installs onto the shaker handle mount using the two hex bolts and washers provided Firebricks The SF250 uses 14 standard firebricks as shown below These standard firebricks measure 9...

Page 5: ...hould con sist of 3 8 millboard or a stove board providing equal protection k 84 R 45 The floor protection should extend 8 to the rear and either side and 16 in front of the stove The floor protection...

Page 6: ...from the stove collar The chimney must be two feet higher than anything within ten feet It also must extend three feet above the point where it intersects or exits the roof line In order to have a pro...

Page 7: ...uld be no more than two 90 elbows or the equivalent used in connecting the stove to the chimney flue H Shared Flue No more than one appliance shall vent into a single flue The most common cause of poo...

Page 8: ...in between Loading Coal should only be added when there is a reasonably hot fire The coal bed should be bright and vigorous If the fire is burning hot and there is a deep bed of coals full loads can...

Page 9: ...After cleaning the chimney any debris will be at the bottom by the clean out door Open the clean out and vacuum the loose debris Clean the smoke pipe from the chimney to the stove using a metal brush...

Page 10: ...supplied nuts on each leg of the coil Place the coil through the holes in the stove and adjust the nuts so that the pipes stick out about 1 to 1 from the sidewall of the stove Put flat wash ers and nu...

Page 11: ...2 Circulating pump method Used when the distance is more than ten feet or when the stove is on a higher level than the existing water heater In addition to a circulator you may want to add a aquastat...

Page 12: ...testing label 12 This appliance is also approved for installation into a shop...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15 Notes...

Page 16: ......

Reviews: