24

P43 Pellet Stove

Exposed    blower  wheel 

and flue opening, NOTE: 

ESP probe is visible.

Blower cover 

removed.

ESP 

probe

6. Remove the ash pan and properly dispose of the 

ashes.

7.  Remove  combustion  blower  cover  by  turning  the 

blower cover latch vertical, see Fig.26. Sliding the 

cover out of the slot on the left.This will expose the 

combustion blower wheel and flue outlet, Fig.27.

8. Clean the combustion blower wheel with a brush and 

a  vacuum  cleaner.  Note:  Do  not  use  a  household 

vacuum  to  clean  the  stove.  We  recommend  that 

you use a shop vacuum that is equipped with a fine 

dust filter called a HEPA filter or a vacuum specially 

made for ashes and soot. 

using a vacuum which is 

not equipped with a fine dust filter may clog and 

disperse fly ash and soot into the room.

 

nOte:  the  StOve  MuSt  be  cOMPletelY 

Out beFOre YOu vacuuM the StOve. live 

PelletS, iF SucKed intO the vacuuM will 

light  the  vacuuM  On  Fire and  MaY  ulti-

MatelY cauSe a hOuSe Fire.

9. Use a brush to clean the flue, being careful not to 

damage the ESP probe, see Fig. 30. The flue goes 

straight through into the vent pipe (Fig.27) therefore, 

the vent pipe can also be cleaned, to some extent,  

through the flue outlet.

 

10. Reinstall the blower cover and close the latch.
11. Slide the ash pan into stove and latch the door.

Fig. 30

Fig. 31

Fig. 33

Be careful not to 

damage ESP probe 

when cleaning with 

brush.

Soot and Fly ash

The  products  of  combustion  will  contain  small 

particles of fly ash which must be removed from the 

inner walls of the stove and from the venting system 

periodically. Removing fly ash and soot improves effi-

ciency, insures that the flue venting passageway is clear 

and unobstructed. The stove should be cleaned after 

each ton of pellets (50 bags) and the venting system 

inspected and cleaned after each heating season.

Maintenance

Burn pot 

Clean-out 

plate

Latch  "open  "with  blower 

cover partly removed. Burn 

pot clean-out is open.

Latch "closed "with blower 

cover  in  place.  Burn  pot 

clean-out is closed.

Fig. 29

Fig. 28

ESP 

Probe

Summary of Contents for P43

Page 1: ...ADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFI...

Page 2: ......

Page 3: ...he surface of the glass door Recommended Non combustible floor protec tion extending beneath any horizontal sections of venting including the T on the back when venting vertically PREVENTION DES INCEN...

Page 4: ...4 Tested to Test ASTM E1509 04 ULC S627 00 and ULC C1482 M1990 WITHOUT SIDE SHIELDS WITH SIDE SHIELDS Ser 008 DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE TIQUETTE MADE IN USA Fabriqu aux U Appareil...

Page 5: ...vice person Periodic cleaning is required throughout the heating seasonandat the end of each winter for the stove to work efficiently See cleaning instruc tions on page 23 Mobile Manufactured Home S t...

Page 6: ...ce to combustible materials allthough some can be installed at 1 clearance Rear Cover Panels Shipping Bolts Note These same holes are used for securing the stove in mobile home installation Fig 1 The...

Page 7: ...k for possible restrictions in the venting configuration or the need for outside air see page 9 For more information on the draft test procedure refer to Page 21 Mobile Home Installation When installi...

Page 8: ...0 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearanc...

Page 9: ...ouse and leaks out at upper levels This air must be replaced with cold air from outdoors which flows into lower levels of the house Vents and chimneys into basements and lower levels of the house can...

Page 10: ...e outlet is more than 12 from the inlet cover The maximum length run of this pipe is 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should be used...

Page 11: ...throughs CAUTION Keep combustible materials such as grass leaves etc at least 3 feet away from the flue outlet on the outside of the building 1 Preferred method This method provides excellent venting...

Page 12: ...cellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 6 In...

Page 13: ...e sure to use ap proved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using th...

Page 14: ...earances Minimum flue vent configuration It is required that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure Min a...

Page 15: ...n off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower Status light error messages 3 Blinks Indicates that the ESP Exhaust Sens...

Page 16: ...required the stove will gradually shut down When the house cools down the stove will automatically bring the room temperature to the precise temperature you desire In the Room Temperature Mode you can...

Page 17: ...he room is already up to temperature The Stove Tempera ture Mode allows you to have a larger fire and a lower sound level without the distribution blower NOTE During the use of this mode if you keep i...

Page 18: ...first fire or you are trying different pellets set the feed adjuster to 4 Fig 17 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well...

Page 19: ...ve a large viewing fire without blowing extra heat into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 o...

Page 20: ...into the burn pot causing excessive smoke on start up 3 The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open 4...

Page 21: ...not allow the feed motor or the igniter to operate C o m b u s t i o n Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted w...

Page 22: ...ged components The glass in your Harman stove is a special ceramic glass Do not abuse the glass by striking or slamming the door Never burn the appliance if the door glass is cracked or broken Replace...

Page 23: ...ld be retained in the closed container until all cinders have thoroughly cooled It is recommended that the stove is cold and shut down when removing the ash pan 1 Lift the latch handle to open the ash...

Page 24: ...ON FIRE AND MAY ULTI MATELY CAUSE A HOUSE FIRE 9 Use a brush to clean the flue being careful not to damage the ESP probe see Fig 30 The flue goes straight through into the vent pipe Fig 27 therefore...

Page 25: ...lated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the rear of the feeder...

Page 26: ...he igniter Poor draft can be caused by blockage in the exhaust excessive build up on the combustion blower fan blades a failed combustion blower or a door or other opening to the firebox not sealed pr...

Page 27: ...all the above 5 6 status blink A 6 blink control board status indication is caused by poor or incomplete combus tion The circuit board has the ability to track the combustion through feed settings an...

Page 28: ...AGRAM 18 3 RUBBER CORD DISTRIBUTION BLOWER COMBUSTION MOTOR CONTACTS N O MALE FEMALE CONNECTIONS BONDED TO STOVE BODY GREEN WIRE IS GROUND POWER CORD 18 3 RUBBER CORD WHITE GREEN BLUE GREEN WHITE RED...

Page 29: ...n one load of pellets The hopper extension adds 60 pounds to the existing hopper capacity allowing you to load 120 pounds of pellets at one time The extension seals to the unit hopper with three latch...

Page 30: ...ontent takes energy to dry and tends to cool the appli ance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pel...

Page 31: ...ture knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot gr...

Page 32: ...continued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition in automatic setting units equipped...

Page 33: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Page 34: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...

Page 35: ...04300 2 charcoal 1 90 04300 3 goldenfire 1 90 04300 4 Metallic blue 1 90 04300 5 honey glo 1 90 04300 10 Mojave red 1 90 04300 12 Forest green beginning Manufacturing date n a ending Manufacturing da...

Page 36: ...t Air Intake Assembly 1 10 06810A 2 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 2 6 UL Feeder Air Intake 1 10 72222 2 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 2 8 Ultra Feeder Weldm...

Page 37: ...r Cover Right 2 00 773828 2P Y 11 Comb Intake Weldment 1 10 08516S Y 12 Retainer Assembly 1 10 08533S Y 13 Ash Pan 1 10 7738108A Y 14 Ash Door Assembly 1 10 7738106A 15 Bolt on Hinge 2 00 06952B 16 Ca...

Page 38: ...use 6 Amp Pkg of 5 3 20 49447 5 Y Gasket 1 4 Rope Black W PSA Per Inch Glass 1 00 2312 Y Gasket 3 8 Rope White LD Per Inch Ash or Load Door 1 00 00888 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y...

Page 39: ...39 P43 Pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 40: ...Proudly Printed On 100 Recycled Paper...

Reviews: