P43 Pellet Stove

        

These units are pre-tested at the factory with exactly 

10 Volts A.C., 60 Hz. They are checked and adjusted 

for firebox tightness, gasket leakage, motor operation 

and igniter operation.  The P43 is then factory set at a 

mid-point adjustment and in most cases will not need any 

adjustments.  

nOte: the factory low draft setting may 

not be correct for the unit's permanent installation 

conditions.

      The control board on the P43 is equipped with a low 

draft adjustment port. Located on the control face just 

to the right of the igniter light. This voltage adjustment 

is  provided  to  allow  the  unit  to  be  adjusted  for  the 

household  voltage  where  the  unit  is  going  to  be  in 

permanent operation. 

nOte: the line voltage varies 

from area to area and often home to home.

     The low draft voltage should be adjusted to achieve 

the most efficient burn on low burn or "maintenance". 

This voltage adjustment allows the installer to change 

the low voltage set point approximately 10 volts.  This 

adjustment should be done by the installer during set 

up because a draft meter reading is 

required 

to insure 

proper set up.

       If the unit is not adjusted properly, it does not cause 

a safety concern. If the unit is adjusted too high, only 

effiency is lost. If the unit is adjusted too low, the low 

draft pressure switch will not allow the feed motor or the 

igniter to operate.

C o m b u s t i o n 

Motor  Speed 

Control

Low  draft  only 

set point.

The small straight 

screwdriver slot is 

plastic; therefore,  

the  unit  can  be 

adjusted while in 

operation.

Fig.

Fig. 3

 

A  simple  draft  test  should  be  performed  after 

completing the flue pipe installation. To record the results 

for future reference:

1.  Plug unit into a 10VAC, 60 HZ outlet.

.  Close the hopper lid, front view door, and the ash pan. 

Neither pellets or a fire are required for this test.

3.  With the mode selector in the "OFF" position, turn 

the feed adjuster to "TEST".

4.  Record the high draft_____in W.C. (Normal is -.50 

to -.60) The control will be on the High Draft for a total 

of  minutes.

5.  After  minutes, the combustion motor will go down to 

low draft and the distribution blower will go on high. Allow 

approximately 15 seconds to pass for the combustion 

motor to slow before checking the low draft.

6.  If the low draft is between -.35 and -.45, record the 

reading _____ in W.C.  If the reading is higher, slowly 

turn  the  set  screw  counter-clockwise  until  the  draft 

lowers. If the reading is lower, very slowly turn the set 

screw clockwise until the draft increases.

nOte: the test mode alternates from high to low 

draft  every  60  seconds.  if  more  time  is  needed 

for  draft  adjustment, wait until the  next  low draft 

cycle.

nOte: in some cases, the draft may not go as low 

as -.35 to -.45 even with the set screw completely 

counter-clockwise. ideally, you should just set it as 

low as possible.

 

low  draft  voltage  adjustment

Draft Meter bolt 

hole location

 

On a P43 the 

draft test hole is under 

the left rear corner of 

the firebox.

P43  low  draft  voltage  adjustment

Summary of Contents for P43

Page 1: ...DA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFIC...

Page 2: ...M R ARRI RE AU PO LE 51 mm 51 mm DU PLAFOND AU DESSUS DU PO LE 457 mm 457 mm DU COIN DU PO LE AU M R DIAGONAL 229 mm 229 mm PR VENIR LES FEUX DE MAISONS OP RER SEULEMENT AVEC LA PORTE D OUVERTURE ET L...

Page 3: ...N ACCORDANCE WITH MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS INSTALLATION INSPECTION IN YOUR AREA EPA EXEMPT PER 40 CFR 60 534 M...

Page 4: ...e should be done by a qualified service person We recom mend that the stove be inspected before use and at least annually by a qualified service person Periodic cleaning is required throughout the hea...

Page 5: ...d the vent pipe is installed to prevent contact with hot or moving parts Firebrick Install the firebrick horizontally on the angle bracket above the burnpot Flame Guide Install the cast iron flame gui...

Page 6: ..._____ If the second reading is more than 05 lower than the first reading check for possible restrictions or the need for outside air see page 9 For more information on the draft test procedure refer t...

Page 7: ...st not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a...

Page 8: ...the stove with high temp silicone caulking Vent Pipe Pellet venting pipe known as L or PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and r...

Page 9: ...houses To install outside air use 2 3 8 I D non combus tible flex pipe There is a break away hole on the rear panel of the P43 stove which must be removed before connecting the flex pipe The pipe shou...

Page 10: ...throughs CAUTION Keep combustible materials such as grass leaves etc at least 3 feet away from the flue outlet on the outside of the building 1 Preferred method This method provides excellent venting...

Page 11: ...to an existing fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questio...

Page 12: ...e sure to use ap proved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using th...

Page 13: ...learances Minimum flue vent configuration It is recommended that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure M...

Page 14: ...t Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower...

Page 15: ...oggle switch is in the Auto position the igniter located inside the burn pot is ready to automatically light the fire when required When the toggle switch set to the Manual position the stove can be l...

Page 16: ...re Mode is if you want to watch a large fire and the room is already up to temperature The Stove Tempera ture Mode allows you to have a larger fire and a lower sound level without the distribution blo...

Page 17: ...fferent pellets set the feed adjuster to 4 Fig 17 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well use that setting Remember if y...

Page 18: ...into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It...

Page 19: ...ive smoke on start up 3 The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open 4 Adjust Feed Rate If this is you...

Page 20: ...r Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 22 Fig 23 A simple draft test should be performed afte...

Page 21: ...air being drawn into the distribution fan NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essential for the P43 s excellent ef ficiency NOTE...

Page 22: ...less pellets and heat output will be greater Note Higher ash content pellets will require more frequent cleanings 1 Shut down stove and disconnect power cord to insure that all motors are stopped 2 C...

Page 23: ...ght through into the vent pipe Fig 27 therefore the vent pipe can also be cleaned to some extent through the flue outlet 10 Reinstall blower cover and relatch 11 Slide ash pan into stove and latch the...

Page 24: ...d male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feed...

Page 25: ...aner to remove all fines 4 Reinstall feed cover wing nut and rear cover panels Fig 39 Pellet Fines will build up in this area 5 16 Hex Head Screws 2 on each side 5 16 Hex Head Screws 2 on each side Th...

Page 26: ...HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or combustion blower has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING O...

Page 27: ...27 P43 Pellet Stove P43 Feeder...

Page 28: ...ght 212 lbs Blower 135 cfm Feed Rate approximate 75lb to 5 5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D inch Fuse Rating 6 amp P43 Specifications 1...

Page 29: ...Tile Grey Slate Options The decorative tile and slate measure 11 938 x 5 938 The tile slate frame is necessary to hold the tile or slate in place on the stove There are 10 decorative tile choices and...

Page 30: ...30 P43 Pellet Stove P43 Wiring Diagram...

Page 31: ...1 605 Control Knob Shaft 3 3 31 015 Front Door Glass 3 40 950133125 Burn Pot Gasket 1 3 44 00409 Tailpipe Gasket 3 44 06179 Wiring Diagram 3 89 06504 Control Panel Sticker 3 90 06655A Owner s Manual 3...

Page 32: ...g acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic bric...

Reviews: