7
Save These Instructions 3-90-798 Dry Seasoned Wood Only!
Oakleaf Woodburning stove
C. Component Locations
d. flue direction Conversion
The Oakleaf features an adjustable flue collar for rear or top exit. Follow these instructions for changing the
direction. First, remove the upper rear heat shield by removing 8 tek screws that secure it. Reaching upward
through the firebox and the open bypass damper, loosen the retainer bolts on each of the flue collar and the cast
iron plate. With the bolts loosened, turn the retainer to allow the piece to come free of the stove body. Reposition
the flue collar and the cast iron plate and secure them with the retainers by tightening the bolts. You will now need
to install a different upper rear heat shield. (See page 23).
Top Load Opening
Air Control
Front Load Door
Top Load Door
Bypass Damper
Control Handle
Ash Door
Ash Door
Latch
Front Load
Door Latch
Level
adjuster
Summary of Contents for OAKLEAF 1-90-797000