![Harman Martin VC-Strip 90357290 User Manual Download Page 14](http://html1.mh-extra.com/html/harman/martin-vc-strip-90357290/martin-vc-strip-90357290_user-manual_4000401014.webp)
14
VC-Strip Safety and Installation Guide
To create a DMX-controlled installation that draws DC power from the Martin Tripix Power IP66:
1. See Figure 7 on page 13 for an overview of this type of installation
2. Make sure that no devices in the installation can be connected to AC mains power until all installation
work is complete.
3. Read “Safety Information” on page 4 and ”Electrostatic discharge precautions” on page 6.
4. Connect VC-Strips together in daisy-chains using Martin™ hybrid PCB-to-PCB cables (see ”VC-Strip to
VC-Strip link cables” on page 28). Connect each cable from the THRU connector on one VC-Strip to the
IN connector on the next VC-Strip.
Warning!
Do not exceed the maximum permitted number of thirty (30) VC-Strip 16x1 modules or sixty
(60) VC-Strip 8x1 modules per chain connected to a Tripix Power IP66.
5. See Figure 8. Connect a Martin™ hybrid-to-PCB adapter cable (P/N 11840158) to the first VC-Strip of
each chain.
6. If necessary, you can extend the hybrid link by connecting a Martin™ 4-pin XLR hybrid extension cable
to the Hybrid-to-PCB adapter cable. Suitable extension cables are available from Martin™ in various
lengths. See ”Extension cables” on page 28.
7. See Figure 8. Connect the DC power input connector of a Martin™ Tripix Power IP66 hybrid lead-in
cable (P/N 11840194) to the DC output on the Tripix Power IP66.
8. Connect the 4-pin female XLR connector on the hybrid lead-in cable to the 4-pin male connector on the
hybrid-to-PCB adapter cable (or on the hybrid extension cable, if you have extended the hybrid link).
9. Connect the 5-pin male XLR connector on the hybrid lead-in cable to a DMX link that carries a DMX
signal from an RDM-compliant DMX controller such as the Martin M1™ or M-PC™.
10. Install a mains power cable on the Tripix Power IP66 and connect it to AC mains power.
11. Apply AC mains power to the DMX controller.
You can now configure the system. See ”System setup”on page 18.
Figure 8: Tripix Power IP66 and DMX connections to a VC-Strip chain
DC power input from
To VC-Strip
Hybrid lead-in cable, Tripix Power IP66, P/N 11840194
chain
5-pin male XLR
4-pin female XLR
4-pin male XLR
PCB connector
Hybrid-to-PCB adapter cable, P/N 11840158
Martin Tripix Power IP66 PSU
DMX from DMX/RDM
controller
Insert 4-pin XLR hybrid
extension cable here if you
need to extend the cable run
Summary of Contents for Martin VC-Strip 90357290
Page 1: ...VC Strip User Manual...
Page 30: ......
Page 31: ......
Page 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...