Field engineering change order
5 of 9
Procedure on solving the red dot issue, number 31072017, date 31-07-2017
Figure 4: Red dot issue
Rearranging the wires correctly
In the affected products, the black wires for LED power
(1) are placed too close to the coil (2) next to the red
LED string. See figure 5 and figure 6.
Due to electrical induction, a current will flow in the
LED circuit and the LED will glow slightly. To avoid this,
you need to place the wires otherwise.
The issue is only of cosmetic matter. There is no risk of
personal injury or damage to the product.
2
1
Figure 5: Position of wires
2
1
Figure 6: Position of wires