44
MAC Aura PXL User Guide
Error messages
Error messages indicate that a problem is present. The MAC Aura PXL communicates errors as follows:
• Error messages flash in the display.
• If more than one error is detected, the fixture flashes all errors three times each.
• Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
• If an error is present, the status LED flashes red.
The possible error messages are listed in Table 8 below
:
Short code
Long message and explanation
CELD
COM ERR LED DRV
LED driver communication error.
COLD
FIXTURE COLD
Fixture too cold. Physical movement of effects is disabled until fixture has warmed up.
FAN
BASE FAN 1 ERR
FAN
BASE FAN 2 ERR
FAN
BASE FAN 3 ERR
FAN
HEAD FAN 1 ERR
FAN
HEAD FAN 2 ERR
FAN
HEAD FAN 3 ERR
FAN
HEAD FAN 4 ERR
FBEP
PAN FBACK ERR
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
FBET
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FBEZ
ZOOM FBACK ERR
Zoom position indexing system timeout. Fixture is unable to correct zoom position.
LDTC
LED TEMP SEN ERR
LED board temperature sensor error.
LDTE
LED TEMP SEN ERR
LED board temperature sensor error.
MMER
MISSING MODULE ERR
Impossible to communicate with a module that should be present. Module missing or not
correctly connected.
PAER
PAN ERROR
Pan position electrical indexing system timeout.
PFTC
PFC TEMP CUT OFF
Power factor correction system temperature cutoff.
PFTE
PFC TEMP SEN ERR
Power factor correction system temperature sensor error.
PSER
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
PTCM
P/T SENSOR ADJUST
Pan/tilt sensors are incorrectly adjusted.
SLER
SAFETY LOOP
Safety loop circuit activated. A temperature circuit breaker has shut down LEDs. Circuit breaker
resets automatically after temperature has returned to normal operating range.
TIER
TILT ERROR
Tilt position electrical indexing circuit timeout.
TSER
TILT SENSOR ERR
Fixture unable to retrieve reliable data from tilt position sensor.
Table 8: Error messages