Harman Martin ERA 500 Hybrid IP User Manual Download Page 14

 14

ERA 500 Hybrid IP User Guide

Fixture setup

The onboard control panel (see “Effects” on page 5) and the Control / settings DMX channel let you 
configure the fixture via a range of fixture settings.

Personality

The ERA 500 Hybrid IP provides several options that let you optimize the fixture for different applications in 
the 

PERSONALITY

 menu:

PAN INVERSE 

and

 TILT INVERSE 

let you invert the direction of pan and tilt movement. This can be a fast 

way of setting symmetrical action in multiple fixtures with no need to reprogram cues.

PAN/TILT SPEED

 lets you set pan and tilt movement to 

FAST

 (optimized for speed) or 

SMOOTH 

(optimized for smooth movement – useful for slow movements in long-throw applications). 

• AUTO LAMP ON

 gives you options for setting the lamp to strike automatically.

• DMX LAMP OFF

lets you decide whether it should be possible to douse the lamp via DMX. The default 

setting is ON (i.e. it is possible to douse the lamp via DMX).

If you want to make it impossible to douse the lamp via DMX by accident (if the lamp is hot this would 
mean a wait of approximately 5 minutes before you can restrike the lamp), change the setting to OFF.

NO DATA MODE 

defines how the fixture reacts if it is powered on but not receiving a DMX signal (for 

example, if the DMX signal is lost during a show).

- If set to 

BLACKOUT

, the fixture will black out.

- If set to 

HOLD

, the fixture will hold all the last DMX values that it received and continue to show its 

current scene. It will continue to show this scene until it receives new DMX signals or it is powered off.

COOLING MODE

 lets you select between two cooling fan options depending on whether your priority is 

highest light output or quietest cooling fan operation:

-

REGULATED FANS

 optimizes cooling fan operation for lowest noise. It operates cooling fans at the 

lowest speed necessary to keep temperatures within their normal operating ranges.

-

FULL

 optimizes cooling fan operation for the lowest possible temperature by setting cooling fans to run 

constantly at full speed.

• DMX RESET

lets you decide whether it should be possible to reset the fixture via DMX with a command 

on the Settings DMX channel. The default setting is ON (i.e. it is possible to reset the fixture via DMX).

If you want to make it impossible to reset the fixture via DMX by accident (if the lamp is hot this would 
mean a wait of approximately 5 minutes before you can restrike the lamp), change the setting to OFF.

• EFFECT SHORTCUT

lets you decide whether the gobo and color wheels should take the shortest route 

to the next slot, even if this means passing through the open position, or whether they should avoid the 
open position even if this means slightly longer changes between some slots. The default setting is ON 
(the fixture takes the shortest route even if this means passing through open).

DISPLAY

 offers the following options for the LCD display in the fixture’s control panel:

-

DISPLAY SLEEP

 gives you options for putting the display into sleep mode, where it blacks out a certain 

period after the last key press on the control panel. If the display is in sleep mode, pressing ENTER will 
activate it again.

-

DISPLAY ROTATION

 lets you rotate the display through 180° so that it is easier to read when the fixture 

is installed with the head hanging downwards. The default setting is AUTOMATIC. With this setting, the 
display rotates automatically through 180° depending on which way up the fixture is installed.

-

DISPLAY INTENSITY

 lets you adjust the brightness of the display backlighting by setting the intensity 

to a level from 10% to 100%. 

-

TEMPERATURE UNIT 

lets you choose whether the fixture should display all temperature readings in 

Celsius or Fahrenheit. 

ERROR MODE

 lets you define how the fixture displays any error messages or warnings:

-

NORMAL

, the default setting, lights up the control panel display and displays any message or warning 

as soon as it is detected.

-

SILENT

 only displays messages and warnings when you access the fixture’s control panel and go to 

SERVICE 

 ERROR LIST.

Summary of Contents for Martin ERA 500 Hybrid IP

Page 1: ...ERA 500 Hybrid IP User Guide...

Page 2: ...ffiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the infor...

Page 3: ...8 Zoom and focus 8 Pan and tilt 8 Control panel 9 Control options 11 DMX 11 RDM 11 Fixture setup 14 Personality 14 Factory defaults 15 Fixture information readouts 15 DMX signal monitoring 15 Test se...

Page 4: ...apply power to the fixture apply power to the power input cable The fixture s Neutrik powerCON TRUE1 connectors can also be connected live or under load Lamp lifetimes The ERA 500 Hybrid IP in combina...

Page 5: ...oarse channel Shutter and strobe effects The ERA 500 Hybrid IP s mechanical shutter provides instant blackout and snap open as well as pulse effects and regular or random strobe effects Dimming Smooth...

Page 6: ...you set the indexed angle or the rotation direction and speed of the gobo that is selected on channel 8 The standard gobos are shown in the correct order in Figure 2 All gobos are interchangeable and...

Page 7: ...n and control type indexing gobo wheel shake and continuous gobo wheel scrolling The gobos on the static gobo wheel are shown in the correct order in Figure 3 Figure 3 Static gobo wheel 1 Gobo 1 Iris...

Page 8: ...effects for maximum punch but will give more even projections when using the fixture as a spot projector Frost Applying the Frost effect softens the beam The heavy frost filter is located in front of...

Page 9: ...a red warning triangle on the right below the DMX address Press the ENTER button to see the messages Display appearance The display flashes if no DMX signal is being received The display can be set to...

Page 10: ...panel A SERV message appears in the display Pan and tilt remain frozen until the next power off power on cycle Important You must use the MENU ENTER key combination immediately after applying power Pu...

Page 11: ...Device Management in accordance with ESTA s American National Standard E1 20 2006 RDM is a bi directional communications protocol for use in DMX512 control systems it is the open standard for DMX512...

Page 12: ...PORTED_PARAMETERS PARAMETER_DESCRIPTION Product information DEVICE_INFO DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SOFTWARE_VERSION_LABEL BOOT_SOFTWARE_VERSION_ID DMX Setup DMX_PERSONALI...

Page 13: ...options 13 Manufacturer specific RDM Parameter IDs GET allowed SET allowed RDM parameter ID s slot 21 22 Notes Fixture behavior LAST_STATE 0XA004 Sets behavior if loss of DMX signal Set to 00 BLACKOUT...

Page 14: ...ooling fan operation for the lowest possible temperature by setting cooling fans to run constantly at full speed DMX RESET lets you decide whether it should be possible to reset the fixture via DMX wi...

Page 15: ...press ENTER to display the current voltage at the fan s input terminals HUMIDITY displays humidity level readouts as percentage relative humidity for the base and the head Excessive humidity can resu...

Page 16: ...be disabled by setting feedback to OFF The OFF setting is not saved when the fixture is powered off and the system will be re enabled the next time the fixture starts If a pan tilt position error occ...

Page 17: ...ant Do not switch the fixture off or disconnect the source of the firmware during an update or the firmware will be corrupted If you update firmware to a newer version check the ERA 500 Hybrid IP area...

Page 18: ...avoid changes in pan and tilt position or changes in effects being visible to the audience or spectators you can set the fixture to black out close the shutter during any of the following Pan and or...

Page 19: ...56 57 63 64 65 66 71 72 73 78 79 80 85 86 87 92 93 94 99 100 101 106 107 108 113 114 115 120 121 122 127 128 190 191 192 193 255 Color wheel Indexing Solid colors Open Color 1 Red Color 2 Aquamarine...

Page 20: ...o rotation CCW slow fast Snap 0 10 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 79 80 84 85 89 90 94 95 99 100 104 105 109 110 114 115 119 120 124 125 129 130 134 135 184 185...

Page 21: ...ight Fade 32768 20 Pan fine LSB 21 0 65535 Tilt MSB Up down Fade 32768 22 Tilt fine LSB 23 0 255 Pan Tilt speed Fast slow Fade 0 24 0 39 40 54 55 69 70 79 80 89 90 99 100 109 110 119 120 129 130 199 2...

Page 22: ...e holds last received data on all channels holds current scene COOLING MODE REGULATED FANS Fan speed optimized for lowest noise temperature controlled by regulating fan speed FULL Fans run at constant...

Page 23: ...Display relative humidity in head BASE xx Display relative humidity in base TEMPERATURE MAIN PCB BASE x x C Scroll through current readings on all PCB temperature sensors main PCB pan tilt PCB CMY PC...

Page 24: ...PAN FOCUS 127 128 127 128 Scroll through effects press ENTER to select Use UP and DOWN buttons to adjust home position Press ENTER to store LOAD DEFAULTS LOAD Load factory default calibration setting...

Page 25: ...R 0X9078 Ballast communication error BASE FAN 1 START ERR 0X9058 Base cooling fan warning BASE FAN 1 STOP ERR 0X9059 Base cooling fan warning BASE FAN 2 START ERR 0X905A Base cooling fan warning BASE...

Page 26: ...lled LAMP FAN1 START ERR 0X905E LAMP FAN1 STOP ERR 0X905F MAGENTA RESET FAIL 0X90A1 Magenta flag reset error PAN ENCODE ERR 0X9010 PAN RESET ERR 0X9012 PCBA CMY COLOR ERR 0X9099 PCBA EFFECT ERR 0X909B...

Page 27: ......

Page 28: ...www martin com...

Reviews: