background image

3-90-70745R16_08/13

SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  FAIlurE TO 

FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.
lISTEd FOr uSE IN ThE u.S. ONlY.  NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES
IF ThIS FIrEPlACE INSErT IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT.  FOr YOur SAFETY, 

FOllOw INSTAllATION dIrECTIONS.  
CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION 
rEQuIrEmENTS IN YOur ArEA.
CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE 

PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.
CETTE guIdE d'uTIlISATION EST dISPONIblE EN FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hArmAN® 

hOmE hEATINg.

SAvE ThESE INSTruCTIONS.

Installation & Operating manual

model(s):

Magnafire Elite Coal Fireplace Insert

NOTICE: SAVE THESE INSTRUCTIONS

hot glass will cause burns.

•  Do not touch glass until it is cooled
•  NEVER allow children to touch glass
•  Keep children away
•  CAREFULLY SUPERVISE children in same room as 

stove.

•  Alert children and adults to hazards of high temperatures.

  high temperatures may ignite clothing or other 

flammable materials.

•  Keep clothing, furniture, draperies and other flammable 

materials away.

hOT SurFACES!

Glass and other surfaces are hot during 

operation and cool down.

WARNING

!

Summary of Contents for Magnafire Elite Coal

Page 1: ...ing department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating save these instructions Installation Operating Manual Model s Magnafire Elite Coal Fireplace Insert NOTICE SAVE THESE INSTRUCTIONS Hot glass will cause burns Do not touch glass until it is cooled NEVER al...

Page 2: ......

Page 3: ...s 8 Wiring Diagram 10 Grate System 11 Warnings Special Instructions 11 Operation Maintenance 12 Warranty 15 Service Maintenance Log 17 Manufactured By a Division of Hearth and Home Technolgies 352 Mountain House Road Halifax PA 17032 www harmanstoves com Contains updated information ...

Page 4: ... of a Magnetic Temperature Gauge to monitor the Insert temperatures relative to the amount of draft at which the customer permits the stove to operate It has been verified that creosote will ignite at 650 degrees Fahrenheit It is the owner s responsibility to follow these recommendations This insert consumes air when it is burning It is advisable that a window in the vicinity be opened slightly wh...

Page 5: ...dware 2 2 INSTALLATION INSTRUCTIONS The minimum fireplace size that your Harman Insert will fit into is 24 high by 31 wide A critical dimension for fit in the fireplace is that you must have 16 1 8 depth minimum at 24 height minimum The first step in installing your new insert is to locate the damper in the top of the fireplace At a minimum the damper must be secured in the open position with wire...

Page 6: ...ntered to allow for easier hole location Next usingthecornerclipsprovidedinthehardwarepackage install the brass trim onto the lid Place the lid onto the blower box and slip the flat head screw downward through the lid and tighten it into the retainer Repeat for both sides Next slide the insert into the fireplace making sure that the front tab of the flue adapter is resting on top of the insert Thi...

Page 7: ...ay the glass into the frame Now lift the load door off of the stove and lay it down onto the glass frame Secure the frame to the door using 4 Flange head bolts provided While the door is still laying flat install the top trim onto the door with 2 Hex head bolts Thecoilspringhandlesslipontothelatchesandtheshaker handle Push while turning to install ASSEMBLY INSTALLATION Grates Grate Link Shaker Bar...

Page 8: ...he chimney D Trees or Other Topographical Barriers Impeding the chimney s operation or causing a down draft condition to exist This can also be caused by adjacent buildings or the roof of the same structure where the chimney is not high enough See Fig H NOTE THE CHIMNEY ON THE HOUSE ILLUSTRATED IS TOO LOW IT SHOULD BE RAISED TO COMPENSATE FOR DRAFTS E ChimneySize Chimneyisnotproperlysizedtoadequat...

Page 9: ...othechimney they may be causing draft problems This must be corrected by your heating contractor 3 4 CHIMNEY DETAILS Chimney Liners Most of the customer inquiries received are problems caused by poor or in some cases excessive draft A result of poor draft could be creosote back puffing and smoky firebox when loading Indications of excessive draft are burning too much fuel and high stack temperatur...

Page 10: ...lectric power at fuse box or circuit breaker panel before making any line voltage connections Follow local electrical codes Be sure to route power so that it doesn t come in contact with the stove IMPORTANT ALL WIRING SHOULD BE DONE IN ACCORDANCE WITH LOCAL AND STATE CODES ...

Page 11: ...t these levels for extended periods of time can damage internal parts of the insert Inserts unlike free standing stoves have no way to release built up heat into your home except through its internal passages Free standing stoves radiate their heat freely into the air Use of the blowers is not only critical to the life of the insert but much heat efficiency is lost if the design of the system is d...

Page 12: ...en the loading door an inch or two for a few seconds before opening completely This method will allow smoke to clear away from thedooropeningbeforetheloadingdooriscompletelyopened Add small compact pieces of hardwood when the kindling is burninghot Keepthedraftcontrolsfullyopentoestablishahot fire quickly The ash door also may be opened during start up to accelarate the intial burn but must be clo...

Page 13: ...OULD BE REDUCED GRATES DAMAGED IN THIS WAY ARE EASILY RECOGNIZED BY THE EXTREME DAMAGE CAUSED TO THE GRATES PLEASE REFER TO YOUR WARRANTY TO SEE THE LIMITSOFLIABILITYINCASESOFABUSEORNEGLECT 8 3 INCREASING HEAT FROM A LOW FIRE Every effort should be made not to let a coal fire burn too long so that the fire has started to die This will cause the reloading process to be much longer and there is a go...

Page 14: ... NOTE ASTOVESHOULDNEVERBELEFTUNATTENDED WITH THE ASH DOOR OPEN WITH THE EXCEPTION OF THE START UP PERIOD THE ASH PAN DOOR SHOULD NEVER BE LEFT OPEN Seriousdamagetothestovecanoccurfromoverheating Coal stoves should not be installed in any chimney that has hadahistoryofback draftingorflowreversal Theseconditions can cause improper draft resulting in carbon monoxide entering the house rather than bei...

Page 15: ...me construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor fo...

Page 16: ...ty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plat...

Page 17: ...17 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Page 18: ...18 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Page 19: ...19 3 90 70745R16_08 13 ...

Page 20: ...100 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA ...

Reviews: