Diagnostic information on page 2 of 6 displays temperature sensors
ESP Temperature: Displays the
current temperature of the Exhaust
Sensing Probe
Room Temperature: Displays
room temperature sensed from
the on-board or Wireless Remote
Sensor(optional).
Return Air Temperature:
Displays the room air temperature
returning to the unit. This
temperature becomes the set
point for the stove to achieve if the wireless sensor loses signal. You will see
“Using Back Up Sensor” on your home screen.
Wireless Sensor: Displays whether or not the optional wireless sensor is
disabled or enabled.
Outside Air Temperature: Displays outside temperature when the optional
Outside Air Kit is installed.
Diagnostic information on Page 3 of 6 displays Limits and Fuel Usage.
Ignition Charge Time (min):
This can only be altered by an
Authorized Harman Dealer.
Displays amount of time the auger
feeds fuel during the ignition cycle.
Feed Rate Limit (%): Displays the
maximum allowed percentage as set
in the “Feed Limit” screen.
ESP Temperature Limit: Displays
the maximum temperature of the
ESP allowed by the control, based
on current settings.
Fuel Used in 24 Hours: Displays the amount of pounds burned in the past
24 hours.
Fuel Used Since Cleaning: Displays how many pounds of fuel was used
since last total clean.
Fuel Remaining: Displays amount of fuel in hopper. To enhance accuracy,
fuel calibration should be completed, see Menu 2.