Troubleshooting
Problem
Possible cause
Remedy
No sound
Power to mixer and/or amplifier
is off.
Switch power to mixer or amplifier
on.
Channel or master fader on
mixer or volume control on
amplifier is at zero.
Set channel or master fader
on mixer or volume control on
amplifier to desired level.
Pickup is not connected to mixer
or amplifier.
Connect pickup to mixer or
amplifier.
Cable connectors are seated
loosely.
Check cable connectors for
secure seat.
Cable is defective.
Check cable and replace if
damaged.
No supply voltage.
Switch phantom power on.
Phantom power supply: connect
to power outlet or insert battery
(batteries). Check cable and
replace if damaged.
Distortions
Gain control on the mixer set
too high.
Turn gain control down CCW.
Mixer input sensitivity too high.
Connect a 10 dB preattenuation
pad between pickup cable and
input.
6
Cleaning
Use a soft cloth moistened with water to clean the surface of the
microphone body.