1
Soundweb
TM
London
BLU-102
Installation Guide
5033748-B
Page 1: ...1 Soundweb TM London BLU 102 Installation Guide 5033748 B...
Page 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...
Page 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...
Page 4: ...Cat 5 fitted with a clip on ferrite sleeve STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cabl...
Page 5: ...d they have OH short for off hook LEDs which illuminate when the phone is off hook Other indicators COM Communications The COM LED turns green to indicate a normal linked condition The COM LED blinks...
Page 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...
Page 7: ...be provided by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configure...
Page 8: ...state or continuous controls such as Parameter Presets or faders See the help file within HiQnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two...
Page 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...
Page 10: ...B 20Hz to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up t...
Page 11: ...ough Latency 4 Fs 0 08ms 48k POWER AND DIMENSIONS Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimension...
Page 12: ...complaint with the FCC if you believe it is necessary f The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If...