All DSP functions are adjusted using the WinControl 
software application. Detailed information on the use of 
WinControl is beyond the scope of this manual, and users 
should consult the WinControl Help files.

Level controls

The gain of each analogue input and each digital input 
may be adjusted independently over the range -70 dB to 
+20 dB. Nominal input level with 0 dB gain is 0 dBV, and 
the maximum input level is +19 dBV (peak).

The source of DSP audio input 1 and 2 (either analogue or 
Dante

) is software configurable.

The output level of each amplifier channel can also be set 
independently, with a range of 80 dB.

Note that after the inputs have been summed, there is 
also a master level control (“Volume”), which provides a 
single-point adjustment of the output levels of all amplifier 
channels.

Polarity (phase) inversion is also available for each input 
and output.

EQ adjustment

The DSP section provides very comprehensive signal 
equalisation for both inputs and outputs. Each analogue 
input and each digital input has its own 4-band parametric 
equaliser. Each amplifier channel has its own 8-band 
parametric equaliser. These provide up to 25 dB of cut or 
boost per band (depending on filter type selected) over the 
range 10 Hz to 24 kHz, with per-band selection of filter type.

Output equalisation can be used to construct crossover 
filtering to allow the IndustryAmps to be used with multi-
way loudspeaker systems. Input equalisation permits 
tailoring of individual input signals for optimum clarity.

Matrix

A matrix is provided so that any of the sixteen inputs can 
be routed to any of the amplifier outputs. Where more than 
one input is selected to go to the same output then the 
inputs are summed.

Autogain

The DSP section includes an autogain algorithm which can be 
set to automatically adjust the overall volume level according 
to the ambient noise level detected by a microphone 
connected at the ANS mic input. The algorithm measures the 
ambient noise in gaps in the programme material being fed 
via the IndustryAmp. Once enabled, the amount of additional 
gain per dB of ambient noise increase can be controlled, as 
well as the threshold at which gain adaption begins.

The autogain algorithm can also be used to provide a level 
attenuation depending on a “volt free” input on the ANS mic 
input (pins ‘+’ and ‘-‘). When the input is open circuit then the 
autogain provides no reduction in overall volume, when the 
input is short circuit the predefined reduction in volume set by 
the autogain comes into affect.

Delay

Delay may be inserted in the output channel of the audio 
signal chain. 

SURVEILLANCE FUNCTIONS

The IndustryAmp incorporates various surveillance features 
to ensure continuous operation in critical applications.

Auto-input switching

Normal configuration of the IndustryAmp is for up to 
sixteen inputs to be permanently summed, so that signals 
on all enabled inputs are always fed through the system 
(matrix selection dependent)

However, if wished, priorities may be assigned to individual 
inputs so that audio through the system is normally derived 
from one input only.  The inputs are then monitored, either 
for presence of pilot tone, or for a continuous signal level 
above a pre-determined threshold. In the event of non-
detection of the pilot tone or input signal, the signal source 
can be switched to that on an alternative input. 

This arrangement is primarily intended to provide 
redundancy; by utilising more than one audio distribution 
path, a high degree of system of security can be gained.

Summary of Contents for AXYS TUNNEL IndustryAmp Dante TUN-590404

Page 1: ...Installation User Manual Applies to Part Numbers TUN 590404 TUN 590804 AXYS IndustryAmp Dante Delivering Clear and Intelligible Messages...

Page 2: ...ISCLAIMER No part of this manual may be reproduced transmitted transcribed stored in a database system or translated without the express written permission of Harman Professional Documentation kept by...

Page 3: ...0 Ventilation 10 Connector and Wiring details 11 AC Mains 11 Audio Connections 12 Analogue inputs 12 Amplifier outputs 12 Dante and Control Interface 13 ANS microphone input 13 Failure relay 14 DSP se...

Page 4: ...receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long...

Page 5: ...analogue inputs plus dual redundant Dante interface 8 x 100W output into 100 ohm load OVERVIEW The AXYS IndustryAmp is a multichannel power amplifier specifically designed for permanent installation i...

Page 6: ...ge protocol by using the Dante Ethernet interfaces Pilot tone detection ANS Ambient Noise Sensing mic input Surveillance failure relay DSP bypass function Universal power supply 100 240 VAC with activ...

Page 7: ...mers Load Monitoring Surge Protection Input 1 Out 1 Out 2 Out 3 Out 4 Input 2 Internal Temperature Fan Monitoring Front LED Internal Supplies Mains External Failure Relay Analogue Pilot detect Digital...

Page 8: ...ut connections may be made The detector will when enabled switch from Input 1 to Input 2 if pilot tone is lost The IndustryAmp incorporates surveillance functions which activate an externally accessib...

Page 9: ...2 13 14 Wiring details for all the rear connectors can be found in subsequent sections of the manual Not present on PB 400 DN 2 Failure relay connector 3 ANS microphone input 4 Analogue input 1 5 Anal...

Page 10: ...ontaining a significant quantity of other heat generating equipment see below consideration should be given to climate controlling the room in which the equipment rack is situated Do not install the I...

Page 11: ...gate why it blew Always replace by a fuse of the same type and rating as indicated on the rear panel and or in the amplifier datasheet NOTE The PowerCon connector should NEVER be plugged in or unplugg...

Page 12: ...IndustryAmp should always be used wherever possible If driving from an unbalanced source use the same wiring as shown above at the amplifier end but connect the hot core to the signal output and the...

Page 13: ...increase the distance further A third party Ethernet to fibre interface will be required in these situations The Dante interfaces add digital audio I O and a control method to the IndustryAmp They pr...

Page 14: ...oving an internal PCB jumper See fig 5 Failure relay In volt free operation CO is connected to NC a failure condition causes CO to be connected to NO When configured for impedance sensing use the impe...

Page 15: ...Dante xmt 12 Dante xmt 13 Dante xmt 14 Dante xmt 15 Dante xmt 16 Dante xmt 17 Dante xmt 1 Dante xmt 2 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 To Dante Outputs Dante xmt...

Page 16: ...han one input is selected to go to the same output then the inputs are summed Autogain The DSP section includes an autogain algorithm which can be set to automatically adjust the overall volume level...

Page 17: ...to 23 5 kHz and the threshold may be set between 10 dBFS and 60 dBFS The amplifier s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or th...

Page 18: ...brated with the normal loads connected to each amplifier channel to establish a reference load current After calibration any partial or total failure of any of the loads or cabling will be registered...

Page 19: ...of the chassis to ground Always connect this terminal 2 Reduction of RF emission Although the IndustryAmp electronics are well shielded and external connections are decoupled to prevent RF emission fr...

Page 20: ...www axystunnel com...

Reviews: