Harman AXYS TUNNEL IndustryAmp Dante PB-400-DN Installation & User Manual Download Page 11

AXYS

®

 IndustryAmp-DN User Manual Rev 3.0

201911/IAMPDN_3.0

11

CONNECTOR AND WIRING DETAILS
AC Mains

AC power is via a rear panel Neutrik

®

 PowerCon

®

 

Type 20 mains connector [14]. A mating mains 

cable (power cord) fitted with a European-style plug is 
supplied with the unit. If the standard AC outlets in the 
territory are of a different type, the correct type of mains 
plug should be substituted, carefully observing the 
following cable colour codes:

CONNECT

COLOUR 

(EUROPE)

COLOUR (US)

Live

Brown

Black

Neutral

Blue

White

Earth (Ground)

Green/Yellow

Green

The IndustryAmp incorporates a “universal” PSU, and will 
operate on all AC mains voltages from 100 V to 240 V.

NOTE:

 The IndustryAmp has an AC mains fuse. 

The fuseholder is on the rear panel [18]. In the 

event of the fuse blowing, always first investigate why it 
blew. Always replace by a fuse of the same type and rating 
as indicated on the rear panel and/or in the amplifier 
datasheet.

NOTE:

 The PowerCon

®

 connector should NEVER 

be plugged in or unplugged while AC mains is 

present. This applies whether or not the amplifier is 
switched on. ALWAYS isolate the AC mains supply at its 
source before plugging or unplugging the connector.

Warning

 - This apparatus is a Class I device and 

must be connected to a mains socket outlet that 

provides a safety ground connection.

Warning

 - Presence of mains voltage is not 

indicated by the LED on the front panel. This LED 

indicates the status of the IndustryAmp and cannot be 
used as a mains voltage indicator.

If the mains switch of the IndustryAmp is not 
readily accessible after installation to disconnect 

the unit when necessary, the mains connection to the 
IndustryAmp should incorporate a manual circuitbreaker 
or an accessible mains plug.

1.

3.

2.

2.

1.

Plugging in

Unplugging

fig.1:  PowerCon Connector

Summary of Contents for AXYS TUNNEL IndustryAmp Dante PB-400-DN

Page 1: ...Installation User Manual Applies to Part Numbers TUN 590404 TUN 590804 AXYS IndustryAmp Dante Delivering Clear and Intelligible Messages...

Page 2: ...ISCLAIMER No part of this manual may be reproduced transmitted transcribed stored in a database system or translated without the express written permission of Harman Professional Documentation kept by...

Page 3: ...0 Ventilation 10 Connector and Wiring details 11 AC Mains 11 Audio Connections 12 Analogue inputs 12 Amplifier outputs 12 Dante and Control Interface 13 ANS microphone input 13 Failure relay 14 DSP se...

Page 4: ...receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long...

Page 5: ...analogue inputs plus dual redundant Dante interface 8 x 100W output into 100 ohm load OVERVIEW The AXYS IndustryAmp is a multichannel power amplifier specifically designed for permanent installation i...

Page 6: ...ge protocol by using the Dante Ethernet interfaces Pilot tone detection ANS Ambient Noise Sensing mic input Surveillance failure relay DSP bypass function Universal power supply 100 240 VAC with activ...

Page 7: ...mers Load Monitoring Surge Protection Input 1 Out 1 Out 2 Out 3 Out 4 Input 2 Internal Temperature Fan Monitoring Front LED Internal Supplies Mains External Failure Relay Analogue Pilot detect Digital...

Page 8: ...ut connections may be made The detector will when enabled switch from Input 1 to Input 2 if pilot tone is lost The IndustryAmp incorporates surveillance functions which activate an externally accessib...

Page 9: ...2 13 14 Wiring details for all the rear connectors can be found in subsequent sections of the manual Not present on PB 400 DN 2 Failure relay connector 3 ANS microphone input 4 Analogue input 1 5 Anal...

Page 10: ...ontaining a significant quantity of other heat generating equipment see below consideration should be given to climate controlling the room in which the equipment rack is situated Do not install the I...

Page 11: ...gate why it blew Always replace by a fuse of the same type and rating as indicated on the rear panel and or in the amplifier datasheet NOTE The PowerCon connector should NEVER be plugged in or unplugg...

Page 12: ...IndustryAmp should always be used wherever possible If driving from an unbalanced source use the same wiring as shown above at the amplifier end but connect the hot core to the signal output and the...

Page 13: ...increase the distance further A third party Ethernet to fibre interface will be required in these situations The Dante interfaces add digital audio I O and a control method to the IndustryAmp They pr...

Page 14: ...oving an internal PCB jumper See fig 5 Failure relay In volt free operation CO is connected to NC a failure condition causes CO to be connected to NO When configured for impedance sensing use the impe...

Page 15: ...Dante xmt 12 Dante xmt 13 Dante xmt 14 Dante xmt 15 Dante xmt 16 Dante xmt 17 Dante xmt 1 Dante xmt 2 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 To Dante Outputs Dante xmt...

Page 16: ...han one input is selected to go to the same output then the inputs are summed Autogain The DSP section includes an autogain algorithm which can be set to automatically adjust the overall volume level...

Page 17: ...to 23 5 kHz and the threshold may be set between 10 dBFS and 60 dBFS The amplifier s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or th...

Page 18: ...brated with the normal loads connected to each amplifier channel to establish a reference load current After calibration any partial or total failure of any of the loads or cabling will be registered...

Page 19: ...of the chassis to ground Always connect this terminal 2 Reduction of RF emission Although the IndustryAmp electronics are well shielded and external connections are decoupled to prevent RF emission fr...

Page 20: ...www axystunnel com...

Reviews: