CONNECTOR AND WIRING DETAILS
AC Mains
AC power is via a rear panel Neutrik
®
PowerCon
®
Type 20 mains connector [14]. A mating mains
cable (power cord) fitted with a European-style plug is
supplied with the unit. If the standard AC outlets in the
territory are of a different type, the correct type of mains
plug should be substituted, carefully observing the
following cable colour codes:
CONNECT
COLOUR
(EUROPE)
COLOUR (US)
Live
Brown
Black
Neutral
Blue
White
Earth (Ground)
Green/Yellow
Green
The IndustryAmp incorporates a “universal” PSU, and will
operate on all AC mains voltages from 100 V to 240 V.
NOTE:
The IndustryAmp has an AC mains fuse.
The fuseholder is on the rear panel [18]. In the
event of the fuse blowing, always first investigate why it
blew. Always replace by a fuse of the same type and rating
as indicated on the rear panel and/or in the amplifier
datasheet.
NOTE:
The PowerCon
®
connector should NEVER
be plugged in or unplugged while AC mains is
present. This applies whether or not the amplifier is
switched on. ALWAYS isolate the AC mains supply at its
source before plugging or unplugging the connector.
Warning
- This apparatus is a Class I device and
must be connected to a mains socket outlet that
provides a safety ground connection.
Warning
- Presence of mains voltage is not
indicated by the LED on the front panel. This LED
indicates the status of the IndustryAmp and cannot be
used as a mains voltage indicator.
If the mains switch of the IndustryAmp is not
readily accessible after installation to disconnect
the unit when necessary, the mains connection to the
IndustryAmp should incorporate a manual circuitbreaker
or an accessible mains plug.
1.
3.
2.
2.
1.
Plugging in
Unplugging
fig.1: PowerCon Connector