Product Specifications and Important Safety Information
A. Appliance Certification / Specifications
C. BTU & Efficiency Specifications
B. Mobile Home Approval
This appliance is approved for mobile and manufactured
home installations when not installed in a sleeping room and
when an outside combustion air inlet is provided.
The structural integrity of the mobile home floor, ceiling, and
walls must be maintained. The appliance must be properly
grounded to the frame of the mobile home and use only listed
pellet vent, Class “PL” or “L” connector pipe.
A Harman
®
Outside Air Kit must be installed in a mobile home
installation.
NOTE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E 1509-12, ULC-S627-00, (UM) 84-HUD
* Weighted average LHV efficiency using data collected
during EPA emissions test.
**Weighted average HHV efficiency using data collected
during EPA emissions test.
***A range of BTU outputs based on EPA Default Efficiency
and the burn rates from the maximum EPA test.
****Based on the maximum feed rate per hour multiplied by
approximately 8600 BTU’s which is the average BTU’s from
a pound of pellets.
This wood heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater
in a manner inconsistent with operating instructions in this
manual.
This wood heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this wood heater in a manner inconsistent with operating
instructions in this manual.
Risk of Fire!
Hearth & Home Technologies disclaims any
responsibility for, and the warranty and agency listing will be
voided by the below actions.
DO NOT:
• Install or operate damaged appliance.
• Modify appliance.
• Install other than as instructed by Hearth & Home
Technologies.
• Operate the appliance without fully assembling all
components.
• Overfire.
• Install any component not approved by Hearth &
Home Technologies.
• Install parts or components not Listed or approved.
• Disable safety switches.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
T H E S T R U C T U R A L I N T E G R I T Y O F T H E
MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
DO NOT INSTALL IN SLEEPING ROOM.
WARNING
!
The
Allure50 is certified to comply with 2020
particulate emission standards.
EPA Certification Number:
50-16
EPA Certified Emissions:
1.48 g/hr
*LHV Tested Efficiency:
79.9%
**HHV Tested Efficiency:
74.6%
***EPA BTU Output:
39,100
****BTU Input
52,600
Vent Size:
3 Inch
Hopper Capacity:
92 lbs
Fuel
Wood Pellet
NOTE:
Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specifications and/or price without notice.
Harman
®
is a registered trademark of Hearth & Home
Technologies.
MODEL:
Allure50 Pellet Stove
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
0135PS037S, 0135PS037E
TYPE:
Pellet Fueled/Supplementary For
Residential Use
STANDARD(s):
ASTM E 2779-10, ASTM E 2515-11,
ASTM E 1509-12, ULC-S627-00,
EPA Method 28R
ELECTRICAL
RATING:
115 VAC, 60 Hz, Start 3.5 AMPS,
Run 2.5 AMPS
GLASS
SPECIFICATION:
5mm mirrored ceramic glass