The
low draft Pressure Switch
is a differential pressure
switch that senses the pressure between the firebox and the
room. If the negative pressure in the firebox becomes too
low for proper combustion, the switch opens, interrupting
power to the feed motor and the igniter. If the switch "opens"
during a rest period, the control will not try to feed or ignite. If
the circuit opens during a feed or ignition cycle, the indicator
lights will remain "on".
The
Control board/ESP
combination is responsible for all
high limit safety control. There are 2 high limits, one normal
operation high limit and one backup high limit. The control
has an automatic diagnostic circuit that continuously monitors
the ESP and Room Sensor for faults. If a fault should occur,
the control sends a status alert and at the same time the
unit goes down to minimum feed/minimum burn as a safety
condition.
motor & Component locations
Accentra Pellet Stove Safety devices
ESP
Low Draft Pressure
Switch
Air Intake Flapper
Feed Motor
Combustion Blower
Distribution Blower
3" Flue Pipe Connector
Summary of Contents for Accentra Freestanding Pellet Stove
Page 43: ......