Harman 5033747-B Installation Manual Download Page 10

10

Technical specifications

FRONT PANEL LED INDICATORS

  

Signal Present, CLIP, 48V (input only)

Other:

  

Control link status and activity for Ethernet and RS-232  

 

connections (COM); Device configuration status (STAT);  

 

Error (ERR); Power/Locate (PWR)

ANALOGUE INPUTS:

  

12 electronically balanced on Phoenix/Combicon    

 

removable screw connectors

Mic/Line Inputs:

  

Nominal gain 0dB, electronically switchable up to +48dB,  

 

in +6dB steps

Input impedance:

  

3.0kOhm 

Maximum input level:

  

+20dBu with 0dB input gain, (+8dBu with 12dB gain) 

Frequency Response: 

 

20Hz to 20kHz +/-0.5dB, balanced, 150 ohm

Dynamic Range: 

 111dB, 20Hz to 20kHz, A-weighted: 108dB unweighted

CMRR:

  

>75dB at 1kHz 

Equiv. Input Noise (EIN):

  

<-125dBu typ. with 150 Ohms source 

Phantom power:

  

48V nominal, selectable per input 

A/D Latency:

  

37/Fs [0.77ms@48k]

AEC:

  

Up to 12 channels of AEC processing

AEC Processing Latency: 

2385/Fs [49.69ms@48k]

(Original 8k Algorithm)

 

AEC Processing Latency:  

1609/Fs [33.52ms@48k]

(Full Bandwidth Algorithm)

  

 

Tail Length:

  

 200 ms

Convergence Rate:

 

 49 dB/s (Average convergence rate)

ANALOGUE OUTPUTS:

  

8 electronically balanced on Phoenix/Combicon  

 

removable screw connectors

Maximum Output Level:

  

+19dBu 

Frequency Response:

  

20Hz to 20kHz (+0.5/-1dB) 

THD:

  

<0.01% (20Hz to 20kHz, +10dBu output) 

Dynamic Range:

  

108dB typ. (22Hz to 22kHz unweighted) 

Output Impedance:

  

40 Ohms balanced and 20 Ohms unbalanced 

Crosstalk:  

<-75dB 

D/A Latency:

  

29/Fs [0.60ms@48k]

Summary of Contents for 5033747-B

Page 1: ...1 Soundweb TM London BLU 101 Installation Guide 5033747 B...

Page 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...

Page 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...

Page 4: ...STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops...

Page 5: ...The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no...

Page 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...

Page 7: ...ded by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for th...

Page 8: ...Qnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL...

Page 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...

Page 10: ...to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 12 c...

Page 11: ...Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weigh...

Page 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in Malaysia...

Reviews: