Harman 391035 Installation & User Manual Download Page 8

AXYS

®

 Octadrive DSP-DN User Manual rev 2.0

201703/ODSPDN_2.0

8

FRONT PANEl

fig.2:  Front Panel

REAR PANEl

fig.3:  Rear Panel

fig.4: Detailed view of Input / Output panel

1. Headphone volume control 
2. Headphone socket 
3. Source selection LEDs 
4.  Headphone source selector 

encoder wheel

5. Power Supply LED
6. Back-up Supply LED
7. Internal Supplies LED
8. Identify LED

9. Failure relay LED
10. Serial Bridge activity LED
11. Mic Level LED
12. Identify LED (rear)
13. Dante

 Primary 

14. Dante

 Secondary

15. ANS/Paging Mic
16. Ambient temperature sensor
17. Control voltage input

18. Failure relay contacts 1
19. Failure relay contacts 2
20. Input 1
21. Input 2
22. Output 1 
23. Output 2 
24. Output 3 
25. Output 4  

26. Output 5 
27. Output 6 
28. Output 7 
29. Output 8 
30. Back-up Supply LED (rear)
31. Back-up Supply connector
32. Power Supply LED (rear)
33. Mains power connector
34. Power switch

16

18

20

22

23

24

25

17

19

21

26

27

28

29

Identify

Primary

Secondary

12

13

14

15 

32

31

30

33

34

1

2

3

4

5 6 7 8 9 10 11

Summary of Contents for 391035

Page 1: ...re of sound reinforcement Installation User Manual AXYS Octadrive DSP DN Dante 8 channel line driver Part No 391035 Note that this manual is valid for hardware series 2 Octadrive DSP DN with serial nu...

Page 2: ...5301 KK Zaltbommel The Netherlands Tel 31 418 515583 Fax 31 418 518077 Zaltbommel March 2017 User s Notice and Disclaimer No part of this manual may be reproduced transmitted transcribed stored in a...

Page 3: ...iring Details 9 AC Mains 9 Back up Supply 10 Analogue Audio Connections 10 Analogue Inputs 10 Analogue Outputs 10 ANS Paging Microphone 11 Failure Relay 11 Dante and Control Interface 12 Ambient Tempe...

Page 4: ...nce receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for l...

Page 5: ...d controlled and monitored using AXYS WinControl software via the Dante Ethernet interfaces Features Eight independent low impedance transformer balanced analogue outputs 19 dBV drive capability Two t...

Page 6: ...Out 1 Input 2 Dante 18 x Digital Outputs ANS Paging Mic Micro Controller Analogue Pilot detect Status LEDs To Outputs Digital Pilot detect x16 PSU Internal Supplies Mains DC Back up Supply Out 2 Out...

Page 7: ...ously monitored for pilot tone with the same auto switching arrangement as the analogue inputs All active inputs as enabled via WinControl are routed to all output channels Pilot tone generation is av...

Page 8: ...Bridge activity LED 11 Mic Level LED 12 Identify LED rear 13 Dante Primary 14 Dante Secondary 15 ANS Paging Mic 16 Ambient temperature sensor 17 Control voltage input 18 Failure relay contacts 1 19 F...

Page 9: ...he territory are of a different type the correct type of mains plug should be substituted carefully observing the following cable colour codes CONNECT COLOUR EUROPE COLOUR US Live Brown Black Neutral...

Page 10: ...ue Inputs The two transformer balanced Analogue inputs are on the connectors 20 and 21 As with other AXYS products e g Intellivox loudspeakers and Industry Amps the normal routing of the input signals...

Page 11: ...ctivate the processed microphone Dante transmit channel For monitored PTT operation the DC impedance between PTT and GND should be 10k activated respectively 20k deactivated PTT control by network com...

Page 12: ...local Ethernet switch es However in many installations the network connection from within a rack to an Ethernet switch will be via structural cabling In this case wire mating RJ 45 plugs not supplied...

Page 13: ...re sensor combined with an ANS microphone is available Part No 971181101 Ambient Mic and Temperature sensor This should be wired using twin twisted pair cable with an overall screen Use one pair for t...

Page 14: ...IN DELAY EQ Dante xmt 2 Dante xmt 1 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 OPTIONAL EXTERNAL MICROPHONE Dante xmt 18 Dante xmt 17 To Dante Outputs Dante xmt 11 Dante x...

Page 15: ...and output equalisers Delay Delay may be inserted in any or all of three locations in the audio signal chain Each output channel may have up to 43 6 s of delay Additionally an overall unit delay of u...

Page 16: ...d may be set between 10 dBFS and 60 dBFS The Octadrive s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or the input can be set auto swit...

Page 17: ...P failure is reported to the WinControl server as well as triggering the external failure relay if configured to do so Status LEDs The front panel carries a set of seven LEDs showing the status of var...

Page 18: ...one of the ten green LEDs 3 being illuminated The level in the headphones may be adjusted with the Volume control 1 Dante Configuration The Dante card fitted to the Octadrive DSP DN is self organising...

Page 19: ...ways connect this terminal 2 Reduction of RF emission Although the Octadrive DSP DN electronics are well shielded and external connections are decoupled to prevent RF emission from the internal high s...

Page 20: ...DURAN AUDIO BV Koxkampseweg 10 5301 KK Zaltbommel The Netherlands tel 31 418 515583 fax 31 418 518077 http www duran audio com Info duran audio com...

Reviews: