Harman TL300 21

Cooking Grill- #1-00-08121

The  TL300  offers  a  unique 

stainless steel cooking grill that 

can easily be taken in and out 

of the stove for easy cleaning. 

Note: Please use heat resistant 

gloves  when  handling  the 

cooking  grill.  Surfaces  will 

be hot enough to cause physical harm.

 

Cozy Screen- #3-40-06960

Your  Harman TL300  can  be  burned  like  a  fireplace 

with the optional Cozy Screen. The Cozy Screen can 

be used with either the door in place or with the door 

removed from the stove. When using the Cozy Screen, 

the damper bypass must stay in the open position or 

smoke spillage will occur.  

The Cozy Screen can be used from the start of a fire or 

can be used with an existing one. When starting a fire 

with the Cozy Screen, smoke spillage may occur until 

it develops a draft strong enough to pull all smoke back 

into the flue.

Trim Kit- #1-00-06931-7

The brushed stainless steel trim kit adds elegance to the 

TL300. The kit includes the 

door frame, ash lip trim, and 

tile frame. 

Blower- #1-00-08118

The optional 105 cfm blower helps 

circulate heated air throughout the 

home.  It  installs  easily  onto  the 

back of the stove, using the included 

mounting plate.

Outside Air (optional)

The TL300 is designed to accommodate the use of 

outside air introduced directly to the stove.  The opening 

is located at the back of the stove pedestal base. You'll 

notice there is a rounded hole with the etching of a larger 

hole. The size needed depends on the length of pipe be-

ing used.(see below)

Check with your local building inspector to find out 

requirements determining if outside air is needed when 

installing the TL300 in your area. Some signs to watch 

for that indicate a possible need for outside air:  Poor 

performance of other heaters or of the TL300, including 

smoke roll-out and odor; the disappearance of the same 

symptoms when a window is opened near the stove; 

and condensation on windows in the winter.  Modern 

homes with tight windows and doors, vapor barriers, and 

particularly with exhaust systems are the most likely to 

require outside air.

An outside air duct less than 5' (1525 mm) long may 

be 3" [80mm] in diameter, and be made of masonry tile, 

26 gauge (0.019) galvanized steel, or other approved 

noncombustible material; it should have a 1" (25 mm) 

clearance to combustibles.  Systems longer than 5' (1525 

mm), or containing more than two elbows, should have a 

4" (100 mm) diameter duct to provide an adequate flow 

of combustion air. The air duct must terminate outside 

the dwelling and be screened to keep out debris, birds 

or animals.

options

3" Outside Air Duct

Summary of Contents for TL300

Page 1: ...ble for installation in a mobile home us only IF THIS wood burning STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to det...

Page 2: ...2 Harman TL300 ...

Page 3: ...re to follow instructions may result in property damage bodily injury or even death Index Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 U S A Introduction 4 Specifications 5 Installation 8 Venting 10 Operation Building a Fire 16 Maintenance 19 Options 21 Service Parts 22 Warranty 26 ...

Page 4: ...EUblES oUAUtrES obJEStAriSqUE Listed soLid FueL FirepLace stove or room Heater appareiL de cHauFFage ou poeLe a combustibLe soLide Model Modele Tl300 Serial NuMber NuMero de Serie CLEARANCE TO COMBUSTIBLE SURFACES A Unit to Sidewall B Unit to Backwall C Chimney Connector to Sidewall D Chimney Connector to Backwall E Unit to Adjacent Wall F Chimney Connector to Adjacent Wall See manual for addition...

Page 5: ...issions Emissons on Low Outside Air Size 525 Lbs 6 inch 18 in 20 in Max 1 500 3000 sq ft 1 1 Grams Per Hr 0 8 Grams Per Hr 3 or 4 inch SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA 223 mm 583 mm 326 mm 6...

Page 6: ...6 Harman TL300 Specifications Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch Top Load Door Top Load Opening ...

Page 7: ...d to rain or extremely damp conditions Hardwoods are favored because they are heavier and contain more heating capacity BTU s per load than do softwoods Wood should be split and stored under cover for seasoning a year is recommended Your stove is not an incinerator do not burn garbage painted or treated wood plastics or other debris Keep the area around the stove free from clutter Keep all combust...

Page 8: ... U S and 60 1524 mm in Canada Due to excessive heat build up at the wall passthrough using double wall pipe horizontal venting is only approved into a masonry chimney See Detailed Clearances on Page 9 Installation Mobile Home Installation The TL300 is approved for mobile home installations in the US only Mobile Home installation should be done in ac cordance with the Manufactured Home and Safety S...

Page 9: ...Only Top vent vented out back wall with 90o elbow Masonry Chim ney Only 21 15 11 2 28 Top vent ceiling and sidewall clearances 28 17 Single Wall Pipe Top Vent Parallel Installation 20 Double Wall Pipe Parallel Installation 18 27 27 18 Corner Installation with Single and Double Wall Pipe 18 5 13 28 17 15 21 775 mm 500 mm 375 mm 775 mm 50 mm 575 mm 425 mm 600 mm 450 mm 775 mm 500 mm 575 mm 425 mm 70...

Page 10: ...ize of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connec tor through a combustible wall if you must use an approved wall pass through described later in this section Assemble the connector beginning at the flue colla...

Page 11: ...hest point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Higher than anything within 10ft of the chimney NOTE The restriction of not venting more than one appliance to the same flue applies to the U S specifically While it is not recommended that you use the ...

Page 12: ...pe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney connector vents to the chimney through the thimble or breech pipe Using a thimble the connector slides completely inside the masonry to the inner edge of the flue liner and may be eas ily removed for chimney and connector inspection...

Page 13: ...Harman TL300 13 Venting Standard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney ...

Page 14: ... Minimum of three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Protection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach Fireplace Conversion with Non Combustible Wall Floor Protection Combustible Floor Damper Closed and Sealed with Non Combus tible Material ...

Page 15: ...sembly 1 Clearance for Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clearance for NFPA 211 Type Approved Thimbles Floor Protecion in Accordance with Solid Fuel Appliance Listing Check with your local building codes for clearance Combustible Wall Sheetrock Airtight insulated Clean out Combustible Floor Floor Protection 15 Damper Closed and Sealed with Noncombustible Material Mantel Tr...

Page 16: ... burned This represents most of the wood s heating capacity The final stage is the charcoal stage where the charcoal burns the remaining heat content out of the fuel Ash re mains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring simultaneously Operation The Combustion Process Two important controls the top load door handle and the air ...

Page 17: ...do not have the proper coal bed Open the bypass damper and continue with the process until a significant coal bed is formed To regulate the speed of the optional convection blower adjust the variable speed control from low to high by turning the knob located on the blower The blower speed should be matched to the air control lever setting When the air setting is low the blower should always be at ...

Page 18: ...r until all cinders have thoroughly cooled This could take days Never use the ash disposal container for other trash Wood ash can be added to your garden or compost g Building and Maintaining the Fire Cont As you begin to operate your stove at higher tem peratures you will notice a hot or unpleasant smell this is just the paint going through the curing process and will disappear after a few fires ...

Page 19: ... The inside of the fire chamber should be examined for damage to the refractory lining material grates and casting If any bricks have been damaged replace them with Harman replacement parts NOTE Be sure not to insert anything such as a fire poker into the Combustion Package Doing this may cause severe damage to the combustion package See below Glass Replacement If the stove s glass is cracked or b...

Page 20: ...ut the added ramp tension needed to keep the damper held in the closed position To adjust the ramp the stove MUST be allowed to go out and cool down After the stove has cooled off remove the stove pipe from the stove collar and close the damper Using a flashlight look into the collar About mid point of the damper plate on the backside you will see the adjustment bolt for the ramp tension See figur...

Page 21: ...tional The TL300 is designed to accommodate the use of outside air introduced directly to the stove The opening is located at the back of the stove pedestal base You ll notice there is a rounded hole with the etching of a larger hole The size needed depends on the length of pipe be ing used see below Check with your local building inspector to find out requirements determining if outside air is ne...

Page 22: ... list on following page Wood Stove 1 90 06900 1 black 1 90 06900 2 charcoal 1 90 06900 3 goldenfire 1 90 06900 4 Metallic blue 1 90 06900 5 honey glo 1 90 06900 10 Mojave red 1 90 06900 12 Forest green beginning Manufacturing date aug 2007 ending Manufacturing date active ...

Page 23: ...2 req 3 31 08724 Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y 8 Left Side Shield 2 00 06926P Y 9 Andrion and Andiron Extensions 2 00 05222 1 Y Screw 5 16 18 x 3 4 Grade 5 Zinc Plated Hex Cap Pkg of 100 3 30 1125 100 Y Washer 5 16 Zinc Plated USS Flat Pkg of 100 3 30 0204 100 Y 10 Front Load Door Assembly 1 10 06920A Door Latch 1 00 249119 Y...

Page 24: ... 2 Wooden Knob 3 40 06956 Y 18 3 Damper Linkage Arm Weldment Includes knob cap 1 10 06937W Y 18 4 Damper Pivot Gear Pkg of 2 2 00 06924 2 18 5 Damper Idler Gear 2 00 06923L Y 18 6 Damper Arm Gear Weldment 1 10 06916W Y 18 7 Damper Shaft Cover Weldment 1 10 06918W 18 8 Damper Linkage Weldment 1 10 249146 Y Hardware Package Includes Drive Arm Washer Pusher Block Bushing Wave Washer Screws 1 00 06901...

Page 25: ...et Brick Left 3 40 00103 Y 19 6 Side Brick Bracket Pkg of 2 1 00 06945 Y 19 7 Fire Brick 6 x 12 Qty 4 req Pre 551 4 40 86125 Y Post 551 3 40 86125 Y 19 8 Brick Insulation Qty 2 req 3 40 06944 Y 19 9 Grate 2 00 06925B Y 19 10 Inlet Brick Right 3 40 00104 Y 19 11 Right Inside Plate Assembly 1 10 249118A Y 19 12 Shoe Brick Gasket 3 44 06951 Y 19 13 Shoe Brick 3 40 00100 Y Harman Gold Label Pkg of 5 3...

Page 26: ...26 Harman TL300 This page intentionally left blank ...

Page 27: ......

Page 28: ......

Page 29: ...Harman TL300 29 Notes ...

Page 30: ...30 Harman TL300 Notes ...

Page 31: ......

Page 32: ...Proudly Printed On 100 Recycled Paper ...

Reviews: