Packing List

       Assembly and Installation

Final Assembly

Remove parts from ash pan.
Install Wooden Door Handle with

1/4 x 20 x 2 1/2  bolt.

Install Brass Hopper Knob with

10-32 x 1/2 bolt.

Install the two Firebricks on the

angle iron behind the burn pot as
shown in fig. 1.

Remove tape from Flame Guide

and make sure it is resting on the burn
pot as shown in fig. 1.

Put the ash pan back in the stove.

Inside Stove:

Hardware Pack

(2) Electrical Terminals
(1) 10-32 x 1/2" Bolt
(1) 1/4 x  20 x 2 1/2" Bolt
(1) Wooden Handle
(1) Brass Knob

(1) Owners Manual
(1) Warranty Activation Coupon
(1) Room Sensing Probe
(1) Ash Pan
(2) Firebricks
(1) Scraper
(1) Flame Guide
(1) Cleaning Brush

Firebricks

Flame Guide

Hopper Knob

Ash Pan

Handle

Fig. 1

Summary of Contents for Invincible RS

Page 1: ...1 R6 INVINCIBLE RS OWNERS MANUAL ...

Page 2: ...ve Company 352 Mountain House Road Halifax Pa 17032 717 362 9080 Packing List 3 Installation Assembly 3 Venting 5 Operation 9 ESP Control 12 Maintenance 13 Wiring Diagram 16 Feeder Parts 17 Trouble Shooting 18 Specifications 19 Warnings 20 ...

Page 3: ...as shown in fig 1 Remove tape from Flame Guide and make sure it is resting on the burn pot as shown in fig 1 Put the ash pan back in the stove Inside Stove Hardware Pack 2 Electrical Terminals 1 10 32 x 1 2 Bolt 1 1 4 x 20 x 2 1 2 Bolt 1 Wooden Handle 1 Brass Knob 1 Owners Manual 1 Warranty Activation Coupon 1 Room Sensing Probe 1 Ash Pan 2 Firebricks 1 Scraper 1 Flame Guide 1 Cleaning Brush Fireb...

Page 4: ...he power cord to a 120 volt recep tacle Prior to installing flue pipe connect draft and meter to stove The draft meter must have a mini mum range of 0 5 Connect stove to 120V power source Set control board to test mode Record draft reading here _______ should read at least 5 After connecting the flue system follow the above procedure However prior to taking the draft reading be sure all doors and ...

Page 5: ...ombustibles of only 3 inches The sections of pipe lock together to form an air tight seal in most cases however in some cases a perfect seal is not achieved For this reason and the fact that the Invincible RS operates with a positive vent pressure we specify that the joints also be sealed with clear silicone Outside Air Outside air is optional except in mobile homes and where building codes requir...

Page 6: ...rred method This method provides excellent venting for nor mal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however four inches allows better access to remove the rear panel The vertical portion of the vent should be three to five feet high This vertical section will provide natural draft in the event of a power failure Fig 5 Fig 6 KEEP COMBUS...

Page 7: ...ner as in method 7 5 Installing into an existing fireplace chimney US only This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate or fiberglass A cap should be installed on the chimney to keep out rain If the chimney condition is questionable you may want to install a lin...

Page 8: ... the sealing system used by the manu facturer Pipe size should be increased to 4 using this method 7 Installing into an existing chimney US and Canada This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure In Canada and some places in the US it is re quired that the vent pipe extend all the way to the top of the chimney ...

Page 9: ...RER Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 DO NOT INSTALL IN SLEEPING ROOM WARNING CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED 3 Keep combustible materials such as grass leaves etc at least 3 feet away from the point directly under the vent termination WARNING ...

Page 10: ...lways turn the mode selector to OFF before selecting the desired mode This resets the control for start up Turn Temp Dial to 7 This will allow the stove to burn at maximum for feed rate adjusting pur poses Apply starting gel to pellets in burn pot and light the gel Close the door after lighting At this point the distribution and combustion lights will be on and the feed motor light will be off As ...

Page 11: ...oom Temp Mode this would be the outer scale marked in degrees In Stove Temp Mode this would be the inner scale marked from 1 to 7 Apply starting gel to pellets in burn pot as shown in fig 10 and light the gel Close the door after lighting At this point the distribution and combustion lights will be on and the feed motor light will be off As the temperature of the fire increases the feed motor ligh...

Page 12: ...m Temp Mode fuel consumption is sac rificed for exact room temperature Therefore as it gets colder more pellets will be burned automati cally The distribution blower speed will vary accord ing to the position of the mode selector fig 13 Shut Down Procedure To kill the fire or stop burning the stove turn the Mode Selector to OFF This will cause the fire to diminish and burn out When the fire burns ...

Page 13: ...t 4 Blinks Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed If a Room Sensing Probe is then installed the status light will automatically reset Note only after unit has warmed up Manual reset disconnect power cord for a few seconds and reconnect If error still occurs call your Dealer Temp dial Allows you to adjust the Room temperature in Room Temp Mode usin...