VENTING
PLEASE NOTE: If your specific venting configuration falls in a box in the venting charts (on pages 10 &
11) that is above the dotted line ( ), you must use one of the approved direct vent venting systems
that utilizes a stainless steel inner liner. The dotted line corresponds to a total vent length of 30 feet includ-
ing vertical rise and horizontal run. This requirement is part of the ANSI standards and is based on testing
conducted to determine where the exhaust gas temperature drops to the point where condensation might oc-
cur in the vent pipe. The standards require the use of corrosion resistant liner materials if that specific total
vent length is exceeded.
VENTING INTO AN EXISTING MASONRY OR CLASS A CHIMNEY
The FireLuxe has been tested and found to be in compliance when using an existing chimney as the air con-
duit for the direct venting system. This type of installation is used when replacing an existing wood-
burning stove with a FireLuxe direct vent gas stove. Check with the venting manufacturer to see if they
have the needed components or kits for this type of installation. Also, check the vent manufacturer’s instal-
lation instructions for the specific details and requirements for this type of installation. The chimney must
be in good condition with no cracks or leaks for this type of installation and the venting components must
be sealed where they meet the existing chimney. Also, check with the local authority having jurisdiction to
see if this type of installation is allowed in your area.