In.addition.to.these.clearances,.adequate.accessibil-
ity.clearance.for.servicing.and.proper.operation.must.be.
maintained.
Do.not.in.any.way.obstruct.the.combustion.air.inlets.
that.are.located.under.the.heater.
If.this.appliance.is.installed.directly.on.carpeting,.tile.
or other combustible material other than wood flooring the
appliance.shall.be.installed.on.a.metal.or.wood.panel.ex-
tending.at.least.the.full.width.and.depth.of.the.appliance.
INSTALLATION
CleaRanCes
The.following.clearances.to.combustibles.must.be.
observed:
Unit.to.left.sidewall.
9".. (230.mm)
Unit.to.right.sidewall.
9".. (230.mm)
Unit.corner.to.walls.
4".. (100.mm)
Rear.of.unit.to.back.wall.
3".. (75.mm)
(measured.from.rear.of.draft.hood.to.wall)
Unit.to.alcove.ceiling.
18".. (460.mm)
Maximum.alcove.depth.
14".. (355.mm)
Due to high temperatures, the Clarity Vented Gas
Heater should be located out of traffic and away
from furniture and draperies.
Children and adults should be alerted to the haz-
ards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the Clarity
Vented Gas Heater.
Clothing or other flammable materials should
not be placed on or near the Clarity Vented Gas
Heater.
Sidewall Clearance
Clearance to Back wall
Clearance from corner of unit to walls
Clearance to alcove ceiling
Maximum alcove depth