7
The Accentra Insert is capable of manual operation. This also allows the operator
to manually control operation during an emergency (i.e. igniter failure, when using a
502H battery backup, or when using certain generators.)
The unit can be switched between "AUTO" and "MANUAL" at any time during
operation.
Igniter Switch to "mANuAl"
room Temperature mode
The fire will have to be lit with starting gel and a
match, or started automatically, see "Automatic Op-
eration". Turn to "Manual" position once the start cycle
begins.
The difference between "AUTO" Room Temperature
Mode and "Manual" Room Temperature Mode is that
the fire will not go out as the room temperature goes
above the control board setting. The unit can only go to
low burn and will remain there until it runs out of fuel or
until more heat is needed and the feed rate increases.
Feed rate adjustments and dial settings are the same
as "AUTO" settings.
Igniter Switch to "mANuAl"
Stove Temperature mode
The advantage of this mode is to allow the operator
to have a large viewing fire without blowing extra heat
into the room.
During operation, with the temperature dial set at #4
or less, the distribution fan will not operate. A #4 on the
temperature dial and a #4 on the feed adjuster is ap-
proximately 80% output. It is not necessary to operate
the distribution blower below this point. Therefore, there
can be a higher feed rate ( a larger viewing fire) without
an excess of hot air blowing into the room.
An example of when to use the Manual Stove Tem-
perature Mode is if you want to watch a large fire and
the room is already up to temperature. The Stove
Temperature Mode allows you to have a larger fire and
a lower sound level, without the distribution blower.
NOTE: during the use of this mode, if you keep
increasing the temperature dial setting to increase
the fire size, the distribution blower will automati-
cally come on when the ESP Temperature reaches
350
o
F, or 81% output.
NOTE: when starting the unit in the "AuTO" mode
and switching to "mANuAl", you may switch at
any time. Once an ignition cycle is started, it will
continue regardless of mode.
manual Ignition/Operation
Room Temperature Mode:
This setting will produce a room temperature
of 70 degrees with the distribution blower at medium speed.
This setting will produce a large viewing fire without a
distribution blower operating.
Fig. 9
manual Stove Temperature mode
Fig. 8