background image

12

11

Instruction of Using Our Products

Instruction of Using Our Products

1. Switch on the power supply

2. Turn on the cold/hot water switch, and adjust to the suitable temperature. Use the switch 

    to choose the faucet or handheld shower to let water in.

3. Don't press the water pump switch unless the water level in the bathtub reach to or 

    higher than the jets position.

4. Use air regulator to adjust the massage power.

5. Rotate the handheld shower to adjust the massage effection.

6. Use light switch to turn on/off the underwater light.

7. Adjust the water divider to use back jets or bottom jets. When the divider handle is in the 

   middle position, you can use both back jets and bottom jets at the same time.
8.  Press pneumatic switch, turn off the pumps, and drain the water after use. Then turn off 

  the power supply.

.

Usage 

Troubleshooting

Trouble

Possible Reason

Try this to solve

Water pump 

Don't work.

Power supply is not well connected, 

the leakage protector disconnect .

Turn on the power supply, and connect 

the leakage protector .
Clean the water pump impeller.

Water pump impeller was stuck 

by sundries.

Press the water pump switch.

The water pump switch is off.

Plug the power supply in.

Power supply plug don't insert or no 

enough power supply.

Repair or replace the water pump.

Water pump trouble.

Air pump don't 

work.

No enough power supply.

Check the circuitry and plug the power 

supply in.

Press the air pump switch.

Switch is off.

Plug the power supply in.

Power supply plug don't insert.

Massage power 

can't be adjusted.

Voltage problem.

Check voltage.

Adjust switch is off or has problem.

Water Circulation is blocked.

Check, replace the switch.

Clean the water circulation.

Bathtub don't 

stand horizontally.

Adjustable foot is not well-adjusted.

Adjust the Adjustable foot.

Water leakage.

Obturating ring is not good.

Replace the obturating ring.

Nut is loose.
Connect part is not well connected.

Screw down the nut.
Pay attention to the connect part 

conglutination

9. Thermostatic heating

This functions works only when the water pump surf function is on.

Press “       ” again to stop the function.
Temperature adjustment

Temperature setting range

35

--45

If the temperature sensor occurs error, LCD displays “E1” and the controller sounds “di…di…”, 

in this case the heater cannot be start. 

Press “       ”   “       ” till the cursor moved to “       ” ,and then press “       ” to start the 

thermostatic heating function.

When the thermostatic heating function is on, press “       ” till “

”on LCD blinks, then press 

 “       ” or “       ” to adjust the temperature. During the adjusting, LCD ddisplays the setting 

temperature, then the temperature shall be increased /decreased 1 

 after press “       ”  “       ” 

once

;

When pressing “       ” or “       ” more that 2S

,

the temperature will increase or decrease 

by“1

 /0.5s”

;

stop adjusting for 5 seconds

,

LCD shall display the current water temperature and 

system exit temperature adjustment.

Thermostatic heating function starts or stops according to the water temperature and set 

temperature

the temperature that the system defaults is 37oC

):

 

Controlling rule is as follows:

If the temperature≥setting temp1

℃,

stop heating and LCD heating symbol blinks

If the temperature≤setting temperature -1

℃,

start heating and LCD heating symbol displayed 

in dynamical way.

NOTE: The heater only maintains the temperature of the water filled into the bathtub 

with the range being 35 degrees Celsius to 45 degree Celsius. It does not increase the 

temperature of the water once filled, but keeps the temperature constant.

Summary of Contents for MT-RT1804

Page 1: ...sage system for 3 minutes Clean the bathtub after stopping the pump and draining off the water 1 The installation should be carried out by a qualified technician and should be according to the manual...

Page 2: ...n to the drop height when go in or out of the appliance 5 Watch out the appliance with suds to avoid slip 6 Don t use acidic and strong alkaline detergent acetone ammonia and so on Clean with alkalesc...

Page 3: ...es which are with good ground line The section of the electrical wire should not be less than 2 5 m The power supply appliance should be in accordance with the National Safety Standard And connect the...

Page 4: ...cet Users need to install the faucet according to the back procedures then connect the cold hot water hose to the corresponding water supply tube which should be in the shelter of the bathtub s back 2...

Page 5: ...corner put the drainer into sewer and seal the drainer with sealant Seal the gap between the bathtub and the wall with sealant to avoid water leakage sealant Installation rocess P 2 As the picture sho...

Page 6: ...stops automatically at the same time the pump icon blinks When any time the system checks the water level achieves the setting value the icon stops blink and the pump starts to work When the system i...

Page 7: ...blocked Check replace the switch Clean the water circulation Bathtub don t stand horizontally Adjustable foot is not well adjusted Adjust the Adjustable foot Water leakage Obturating ring is not good...

Reviews: