12
11
Instruction of Using Our Products
Instruction of Using Our Products
1. Switch on the power supply
2. Turn on the cold/hot water switch, and adjust to the suitable temperature. Use the switch
to choose the faucet or handheld shower to let water in.
3. Don't press the water pump switch unless the water level in the bathtub reach to or
higher than the jets position.
4. Use air regulator to adjust the massage power.
5. Rotate the handheld shower to adjust the massage effection.
6. Use light switch to turn on/off the underwater light.
7. Adjust the water divider to use back jets or bottom jets. When the divider handle is in the
middle position, you can use both back jets and bottom jets at the same time.
8. Press pneumatic switch, turn off the pumps, and drain the water after use. Then turn off
the power supply.
.
Usage
Troubleshooting
Trouble
Possible Reason
Try this to solve
Water pump
Don't work.
Power supply is not well connected,
the leakage protector disconnect .
Turn on the power supply, and connect
the leakage protector .
Clean the water pump impeller.
Water pump impeller was stuck
by sundries.
Press the water pump switch.
The water pump switch is off.
Plug the power supply in.
Power supply plug don't insert or no
enough power supply.
Repair or replace the water pump.
Water pump trouble.
Air pump don't
work.
No enough power supply.
Check the circuitry and plug the power
supply in.
Press the air pump switch.
Switch is off.
Plug the power supply in.
Power supply plug don't insert.
Massage power
can't be adjusted.
Voltage problem.
Check voltage.
Adjust switch is off or has problem.
Water Circulation is blocked.
Check, replace the switch.
Clean the water circulation.
Bathtub don't
stand horizontally.
Adjustable foot is not well-adjusted.
Adjust the Adjustable foot.
Water leakage.
Obturating ring is not good.
Replace the obturating ring.
Nut is loose.
Connect part is not well connected.
Screw down the nut.
Pay attention to the connect part
conglutination
9. Thermostatic heating
This functions works only when the water pump surf function is on.
Press “ ” again to stop the function.
Temperature adjustment
Temperature setting range
:
35
℃
--45
℃
If the temperature sensor occurs error, LCD displays “E1” and the controller sounds “di…di…”,
in this case the heater cannot be start.
Press “ ” “ ” till the cursor moved to “ ” ,and then press “ ” to start the
thermostatic heating function.
When the thermostatic heating function is on, press “ ” till “
℃
”on LCD blinks, then press
“ ” or “ ” to adjust the temperature. During the adjusting, LCD ddisplays the setting
temperature, then the temperature shall be increased /decreased 1
℃
after press “ ” “ ”
once
;
When pressing “ ” or “ ” more that 2S
,
the temperature will increase or decrease
by“1
℃
/0.5s”
;
stop adjusting for 5 seconds
,
LCD shall display the current water temperature and
system exit temperature adjustment.
Thermostatic heating function starts or stops according to the water temperature and set
temperature
(
the temperature that the system defaults is 37oC
):
Controlling rule is as follows:
If the temperature≥setting temp1
℃,
stop heating and LCD heating symbol blinks
;
If the temperature≤setting temperature -1
℃,
start heating and LCD heating symbol displayed
in dynamical way.
NOTE: The heater only maintains the temperature of the water filled into the bathtub
with the range being 35 degrees Celsius to 45 degree Celsius. It does not increase the
temperature of the water once filled, but keeps the temperature constant.