![Harken MKIV Installation Manual Download Page 16](http://html1.mh-extra.com/html/harken/mkiv/mkiv_installation-manual_597556016.webp)
Assembly Foils/Connectors
16
MKIV Unit 1
Loctite is a registered trademark of Henkel AG & Company KGaA.
Use bushings, connector, wedge and
adhesive in other screw hole and
insert into other foil. Use 1/3–1/2 ml
of adhesive.
Inject only a small amount of adhesive into
middle hole. Unit 1 will only take 1/3–1/2
of a graduation mark.
Tip: When you see a small amount of
adhesive enter one of the screw holes,
stop. You have applied enough adhesive.
Use “ml”
marks to
estimate
1
/
3
to
1
/
2
ml
of adhesive
Stop when you see a small
amount of adhesive enter
one of the screw holes.
Tighten screws into connector holes. Make
sure a drop of red Loctite
®
entered each
screw hole. If not, apply to screw.
Red Loctite
®