![Harken FlatWinder 250 Installation And Maintenance Manual Download Page 15](http://html1.mh-extra.com/html/harken/flatwinder-250/flatwinder-250_installation-and-maintenance-manual_597552015.webp)
15
FlatWinder
TM
250-500
Installation and Maintenance Manual
Refer to the following chart for wire size:
Total distance between FlatWinder
TM
and battery
Current
voltage
Under 16.4 ft
AWG
Under 5 m
mm
2
16.4 - 32.8 ft
AWG
5 m - 10 m
mm
2
32.8 - 49.2 ft
AWG
10 m - 15 m
mm
2
49.2 - 65.6 ft
AGW
15m - 20 m
mm
2
12 V
2
32
0
50
00
70
000
95
24V
5
16
3
25
2
35
0
50
NOTICE
To connect motor, attach cable terminals to
clamps between nut and lock nut. Hold nut in
contact with motor using a spanner and tighten
other nut with second spanner. Take special care
not to turn the central spindles. Be careful not to
turn central spindles. These instructions apply
when assembling and disassembling. We
recommend using a torque wrench so as to obtain
a torque equal to and no greater than 10 Nm (88
in-lb).
NOTICE
Note that correct electrical contact sequence is:
Nut – Cable Terminal – Self-Locking Washer –
Lock Nut
Summary of Contents for FlatWinder 250
Page 1: ...MFW 02 Installation and Maintenance Manual FlatWinderTM 250 500 ...
Page 6: ...6 FlatWinderTM 250 500 Installation and Maintenance Manual Outline FlatWinderTM 250 ...
Page 19: ...19 FlatWinderTM 250 500 Installation and Maintenance Manual Exploded view FlatWinderTM 250 ...
Page 21: ...21 FlatWinderTM 250 500 Installation and Maintenance Manual FlatWinderTM 500 ...