Planning Installation - Dimensions
2
Make sure organizer is positioned so it bisects the angle of the lines. If organizer does
not bisect angle the maximum working load is reduced.
WARNING! You must mount to solid deck construction using specified fasteners in
all mounting holes and nuts, washers or backing plates to achieve correct maximum
working load to avoid a failure leading to an accident.
A
B
C
D
Description
A Height
B End to fastener
C Fastener spacing
D Fastener to end
mm
in
mm
in
mm
in
mm
in
40 mm
24
.95
40.8
1.61
43.13
1.698
20.0
.79
50 mm
30
1.19
53.7
2.11
56.01
2.205
25.0
.98
Planning Installation - Deck Strength
Determine if deck is strong enough for mounting the organizer. Make sure all sheaves
have fasteners that are through bolted using nuts, large washers or backing plates.
Cored decks must have solid inserts such as G-10 plates sized to distribute the load.
IMPORTANT! When organizers are double stacked, more load is put on the deck due to
leverage load of longer screws. Be sure deck construction is strong enough.
Flathead fastener size
40 mm Organizer - 6 mm - 1/4"
50 mm Organizer - 8 mm - 5/16
Through bolted using large washers and nuts
Solid deck construction
Planning Installation - Bisecting Line Angle
Correct
Incorrect