background image

HARGROVE

Woodland Glow

Vent Free Room Heater

Operation and Installation Guide

Natural Gas

and

Propane (LP)

Models

WARNING:

Improper installation, adjustments, alteration,

service, or maintenance can cause personal injury or property
damage.  Refer to this manual.  For assistance or for additional
information, consult a qualified installer, service agency or the
gas supplier

.

This appliance is de-
signed to supplement a
current heating system.
It is not designed to be
used as a primary heat
source.

This appliance operates as an unvented room
heater when fitted to a solid fuel burning
masonry or factory built fireplace

with the flue

damper closed.

  It may also be installed in an

approved unvented fireplace (approved models
listed on page 1 in installation guide).

WARNING:

 THIS IS AN UNVENTED GAS-

FIRED HEATER.  IT USES AIR (OXYGEN)
FROM THE ROOM IN WHICH IT IS
INSTALLED. PROVISIONS FOR ADEQUATE
COMBUSTION AND VENTILATION AIR MUST
BE PROVIDED.  REFERENCE NATIONAL
FUEL GAS CODE NFPA 54, ANSI Z223.1.
REFER TO PAGE 2 OF THE INSTALLATION
INSTRUCTIONS

.

This appliance is only for use with the type of
gas indicated on the rating plate.  This appliance 
is not convertible for use with other gases.Solid
fuels shall not be burned in a fireplace where an
unvented  room heater is installed.

WARNING: If information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 
any other appliance.

-WHAT TO DO IF YOU SMELL GAS

* Do not try to light any appliance.
* Do not touch any electrical switch; do not use any phone in your building.
* Immediately call your gas supplier from a neighbor's phone.  Follow the
  gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or 
the gas supplier.

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for Woodland Glow

Page 1: ...E COMBUSTION AND VENTILATION AIR MUST BE PROVIDED REFERENCE NATIONAL FUEL GAS CODE NFPA 54 ANSI Z223 1 REFER TO PAGE 2 OF THE INSTALLATION INSTRUCTIONS This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Solid fuels shall not be burned in a fireplace where an unvented room heater is installed WARNING If inform...

Page 2: ...ireplace Dimensions Clearances 4 Minimum Clearances to Combustible Materials 4 5 Mantle Clearances 5 9 INSTALLATION 5 Fireplace Preparation 6 7 8 Log Placement Gas Line Hook Up 9 Volcanic Cinder 10 11 OPERATION 10 Lighting Instructions 11 11 Important Safeguards 11 Cleaning Servicing Controlling Heat Output 12 PARTS IDENTIFICATION 13 ASSEMBLY IDENTIFICATION 14 15 TROUBLE SHOOTING 16 LIMITED WARRAN...

Page 3: ... hot furnace register or an open door WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS 4 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Young children should be carefully supervised when they are in the same room with the appliance 5 Children and adults should be alerted to...

Page 4: ... support STEP THREE ADD THE BTU Hr OF ALL THE FUEL BURNING APPLIANCES IN THE SPACE VENT FREE HEATER __________ BTU Hr GAS APPLIANCE 1 __________ BTU Hr GAS APPLIANCE 2 __________ BTU Hr Total __________ BTU Hr Example VENT FREE HEATER 26 000 BTU Hr GAS APPLIANCE 1 35 000 BTU Hr Total 61 000 BTU Hr NOTE DO NOT INCLUDE DIRECT VENT GAS APPLIANCES DIRECT VENT IS SEALED COMBUSTION AND DRAWS COMBUSTION ...

Page 5: ... clockwise for min heat Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 for each 1 000 feet above sea level Refer to the National Fuel Gas Code WARNING OPERATION OF THIS APPLI ANCE ON GASES FOR WHICH IT IS NOT EQUIPPED MAY LEAD TO CARBON MON OXIDE POISONING Fireplace Dimensions and Clearances Refer to...

Page 6: ...scoloration will never occur The possibility of heat damage exists whether burning wood or gas logs Refer to Fig 2 for the following dimensions A Minimum left and right clearance to combustible walls 15 B Minimum clearance to combustible ceiling 42 C Minimum left and right side clearance to mantle 6 Fig 2 Minimum Clearances to Combustible Materials 8 8 10 8 2 5 to 6 26 28 30 10 6 2 5 8 12 16 8 2 5...

Page 7: ...S U S Requirement 5 95 The installation must conform with state and local codes or in absence of local codes with the National Fuel Code ANSI Z223 1 WARNING ANY MODIFICATION TO THIS UNVENTED GAS HEATER OR ITS CONTROLS CAN BE DANGEROUS IMPROPER INSTALLATION OR USE OF THE HEATER CAN CAUSE SERIOUS IN JURY OR DEATH FROM FIRE BURNS EXPLOSION OR CARBON MONOXIDE POISONING WARNING GLASS DOORS MUST BE OPEN...

Page 8: ... free units 2 The incoming gas line may be routed into the fireplace either from the left or right side 3 Include a manual shutoff valve in the gas supply line so the appliance may be disconnected for servicing 4 Center the burner system from side to side in the firebox In a vented firebox if the damper is used the burner assembly should be located directly under the damper 5 Use the 3 8 aluminum ...

Page 9: ...r positioning Back Log Medium sized flat log with two notches for positioning 3 Place the pedestal grate clips on the farthest back tabs of the burner system Align the tabs IMPORTANT Don not use this appliance if any part has been submerged under water Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been u...

Page 10: ...K LOG FRONT LOG BURNER ASSEMBLY COMPLETE SET DO NOT ALLOW THE FLAMES TO COME IN CONTACT WITH THE TOP LOGS A PERIODIC CHECK OF THE MAIN BURNER FLAMES SHOULD BE PERFORMED STEP 4 Log Placement TOP LOGS INSTALLATION Pg 8 MIDDLE LOG ...

Page 11: ... that is supplied in the accessory kit Pour the Volcanic Cinder on the floor of the fireplace around and under the burner system Fig 8 SUGGESTION The Volcanic Cinder can be used to cover up the LIGHTING INSTRUCTION tags and Rating Plate DO NOT detach these tags This will void the manufacturers warranty WARNING DO NOT pour the Volcanic Cinder on the burner system or around the pilot Pg 9 ...

Page 12: ...ime should the LIGHTING INSTRUCTION tags be detached from the burner system Removing the tags will void the manufacturer s warranty Fig 10 GAS CONTROL 6 Once in the IGN position push the knob in as far as it will go This action releases gas flow to the pilot If the control knob is not held in all the way the pilot will not stay lit when the knob is released 7 While holding in the Pilot Ignitor Kno...

Page 13: ...ll occur Cleaning and Servicing Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control components burners and circulating air passageways of the appliance be k...

Page 14: ...18 NG GV MAX 18 LP GV MAX 24 NG GV MAX 24 LP 4 Pilot Regulator Assembly PIL REG 4 PIL REG 10 PIL REG 4 PIL REG 10 5 Oxygen Depletion System Assembly ODSA NG ODSA LP ODSA NG ODSA LP 6 Back Log Bracket not pictured BKT BL BKT BL BKT BL BKT BL 7 Aluminum Connector not pictured AC 18 AC 18 AC 18 AC 18 8 Gas Fire Logs not pictured 6 Logs 6 Logs 6 Logs 6 Logs 21 SETS 24 30 SETS WARNING Failure to positi...

Page 15: ...ASSEMBLY IDENTIFICATION Pg 13 2 front 1 3 4 5 2 back ...

Page 16: ...not fully open 4 Thermocouple connection loose at valve 5 Pilot flame not touching thermo couple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damage 7 Control valve damage 1 Not enough fresh air is available for ODS pilot to operate 2 Low gas pres...

Page 17: ...bstruction pipe dope teflon tape etc 1 Burner orifice is clogged or damaged REMEDY 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position then depress knob 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Clean ODS pilot 1 Locate and correct all leaks 2 Contact dealer to receive fu...

Page 18: ...anty applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRIT...

Reviews: