background image

OPERATION 

 
 
 
 
 
 
 
 
 

Controlling Heat Output 

 

 

 

Cleaning And Servicing 

 

 

 
 
 
 
 
 
 
 
 
 

Important Safeguards 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TO TURN OFF GAS TO APPLIANCE 

 

TEMPORARY SHUTDOWN PROCEDURE: 

To turn off main burner only, depress the knob and turn it 
clockwise            as far as it will go.  Do not force. 

 
COMPLETE SHUT-DOWN PROCEDURE: 

Turn off all electrical power in firebox.  Turn gas control 
knob clockwise to the “OFF” position. 

 

* The heat output can be controlled by adjusting the 
vent free burner control knob. 
 
* Another way to regulate the heat output is to open 
the fireplace damper.   
   If you want: 

a.  more heat radiated into the room – Keep the 

damper completely closed                         

b.  less heat radiated into the room – open the 

fireplace damper to varying degrees.  

1.  To avoid personal injury, do not touch hot 
surfaces when the appliance is operating.  Touch 
only the piezo ignitor and control knob. 
 

Hot Surfaces 
a.  Grate 
b.  Burner 
c.  Logs 
d.  Surfaces above the opening of the 

fireplace 

 
2.  Although your gas logs are very realistic in 
appearance, it is not a real wood-burning fireplace 
and must not be used for burning any material. 
 

 

*  To avoid irreparable damage to the appliance or 
personal injury, matches, paper, garbage, or any 
other material must not be placed or thrown on top of 
the logs or into the flames. 
 
Close supervision is necessary when the appliance is 
being operated near children. 
 
Avoid any drafts that alter burner patterns.  Do not 
allow fans to blow directly into the fireplace.  Ceiling 
fans may create drafts that alter burner flame 
patterns.  Sooting and improper burning will occur.

 

Installation and repair should be done by a qualified 
servi ce person.  The appliance should be inspected 
before use and at least annually by a professional service 
person.  More frequent cleaning may be required due to 
excessive lint from carpeting, bedding, and material, etc.  
It is imperative that control components, burners and 
circulating air passageways of the appliance be kept 
clean. 

 

• 

If the flames show any unusual shapes or 
behavior, or the burners fail to ignite 
properly, then the burner holes may require 
cleaning. 

 

WARNING:

  

TURN OFF VENT FREE BURNER 

SYSTEM AND ALLOW TO COOL BEFORE CLEANING 
OR SERVICING. 
 

MONTHLY CLEANING 

1.  If removing logs, when reinstalling, refer to “Log 

Assembly Diagram” for correct log placement. 

 
2.  Do not use cleaning fluids to clean logs or any part of 

the heater. 

 

3.  Brush logs with a soft bristle brush or vacuum with 

brush attachment. 

 

4.  Vacuum loose particles and dust from the front and 

rear burner ports, gas control, piezo cover, and grate. 

 

5.  Inspect and clean ODS pilot for operation and 

accumulation of lint at air intake holes. 

 

6.  Verify flame pattern and log placement for proper 

operation. 

 

7.  Verify smooth and responsive ignition of main burner 

and rear burner.  Refer to page         for proper 
pictorial sketch of proper operation. 

 

ANNUAL CLEANING AND INSPECTION 

1.  Dealer or qualified inspector – follow the above steps 

for proper servicing and inspection. 

 

16 

Summary of Contents for Timberland Glow

Page 1: ...age Refer to this manual For assistance or for additional information consult a qualified installer service agency or gas supplier This appliance is only for use with the type of gas indicated on the...

Page 2: ...5 Gas Line Hook Up 6 Gas Pressure Check 7 Wiring Schematic Millivolt Units Only 7 Log Placement Timberland Glow 22 Model 8 Log Placement Timberland Glow 26 Model 9 Log Placement Highland Glow 22 and...

Page 3: ...sed by a ceiling fan near the fireplace a hot furnace or an open door WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS 4 Due to high temp...

Page 4: ...room can support STEP THREE ADD THE BTU Hr OF ALL THE FUEL BURNING APPLIANCES IN THE SPACE VENT FREE HEATER_________________BTU Hr GAS APPLIANCE 1 _________________BTU Hr GAS APPLIANCE 2 ____________...

Page 5: ...ins WC 11 ins WC 4 ins WC 10 ins WC When operating the main burner use the control knob to raise and lower the min and max heat output Turn the control knob counterclockwise for max heat and clockwis...

Page 6: ...fire In most cases they should also be adequate to prevent any discoloration or warping due to heat However each Gas Log installation will present unique circumstances creating many variables beyond...

Page 7: ...rm with state and local codes or in absence of local codes to the National Fuel Gas Code ANSI Z223 1 IMPORTANT Before installing in a solid fuel burning fireplace the chimney flue and firebox must be...

Page 8: ...3 Include a manual shutoff valve in the gas supply line so the appliance may be disconnected for servicing 4 Center the burner system from side to side in the firebox In a vented firebox if the dampe...

Page 9: ...technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 7 CAUTION Label all wire prior to disconnection when servicing controls...

Page 10: ...of the left Back Log The branch from the top log faces forward and will rest on the left Front Log Fig 2 3 1 2 3 4 5 Back Logs Front Logs Top Log Back Burner Plate Front Burner Plate Fig 1 Fig 2 Fig 3...

Page 11: ...Install the right Top Log by placing the holes in the bottom of the right Top Log over the pins in the right Front Log The small branch on the right Top Log faces back and will rest on the extension...

Page 12: ...back and front log The branch should be facing forward Fig 1 2 Step 5 Install the right Top Log 5 by placing the flat side of the log on the notches on the top side of the back and front log The branc...

Page 13: ...RIAL INTO THE BURNER PORTS WARNING DO NOT PUT ANY ADDITIONAL EMBER MATERIAL ON THE BURNER SYSTEM USE ONLY WHAT WAS PROVIDED WITH THE SET PLACING ADDITIONAL EMBER MATERIAL ON THE SET MAY CAUSE IMPROPER...

Page 14: ...NDER ON THE BURNERS OR AROUND THE PILOT 2 You may use the Volcanic Cinder to cover up the Lighting Tags that are attached to the set DO NOT REMOVE THE LIGHTING TAGS FROM THE BURNER SYSTEM THIS WILL VO...

Page 15: ...smell gas go to the next step 5 Turn the Control Knob counterclockwise to the PILOT position 6 Push in control knob and hold it in 7 Light the pilot mounted in the front of the back burner by pushing...

Page 16: ...rclockwise to the IGN ignition position 6 Once again the IGN position push the knob in as far as it will go This action releases gas flow to the pilot 7 While holding in the Pilot Ignitor Knob turn it...

Page 17: ...ve on this label If you do not smell gas go to the next step 5 Depress the control knob and turn counterclockwise to the PILOT position LIGHTING INSTRUCTIONS WARNING At no time should the LIGHTING INS...

Page 18: ...erns Do not allow fans to blow directly into the fireplace Ceiling fans may create drafts that alter burner flame patterns Sooting and improper burning will occur Installation and repair should be don...

Page 19: ...REGULATOR 1G NG 1 REG 4 REG 4 REGULATOR 1G LP 1 REG 10 REG 10 N SPARK IGNITOR 1G 1 SIT PIEZO SIT PIEZO O 1 8 FIP X 3 8 COMPRESSION 2 70 6 2 70 6 2 P 3 8 STREET ELBOW 1G 1 SE 6 SE 6 Q 3 8 ML X 3 8 FL 1...

Page 20: ...VALVE 1 SIT MIL NG VAVLE SIT MIL NG VALVE CONVERSION FOR NATURAL GAS 1 SITMILCNG SITMILCNG CONVERSION FOR LIQUID PROPANE GAS 1 SITMILCLP SITMILCLP G SPARK IGNITOR 1 SIT PIEZO SIT PIEZO H 3 8 ML X 3 8...

Page 21: ...lve not fully open 4 Thermocouple connection loose at valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one...

Page 22: ...paint fumes cleaning agents pet hair or other particles are cycling thru the fireplace when it is operating 2 Gas leak 1 Logs are not positioned properly and are obstructing the flame 2 Main burner h...

Page 23: ...y applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limita...